Related Experiment Video
Updated: Jan 29, 2026

Enucleation of the Prostate for the Treatment of Benign Prostatic Hyperplasia Using a 980 nm Diode Laser
Published on: May 5, 2020
A Case Series on the Efficacy and Safety of Transperineal Laser Ablation for Benign Prostatic Hyperplasia
Malone R Locke1,2, Donald Russell Locke3
1Department of Urology, University of Arizona, Tucson, AZ 85724, USA.
Abstract:
Background/Objectives: Traditional surgeries for benign prostatic hyperplasia (BPH), such as transurethral resection of the prostate (TURP), carry risks including sexual dysfunction and extended recovery. EchoLaser transperineal laser ablation (TPLA) offers a minimally invasive alternative with potential benefits in preserving sexual function and reducing recovery time. This exploratory study evaluated the safety and efficacy of EchoLaser TPLA for the treatment of prostate-related voiding symptoms. Methods: This retrospective, single-center study enrolled seven patients with lower urinary tract symptoms due to BPH. TPLA was performed under local anesthesia, and follow-up was conducted at 1, 3, 6, and 12 months. The primary outcome was measured by the International Prostate Symptom Score (IPSS). Secondary outcomes included PSA levels, prostate and transition zone (TZ) volume, Qmax, post-void residual (PVR) volume, quality of life (QoL) score, Sexual Health Inventory for Men (SHIM) score, and Male Sexual Health Questionnaire to assess for ejaculatory dysfunction (MSHQ-EjD) score. Results: Statistically significant improvements in IPSS, Qmax, PVR, and QoL relative to baseline were observed at 1 month post-treatment, and these improvements remained significant throughout the 12-month follow-up period. Post-treatment reductions in PV and TZ volume were statistically significant at 6 months; while PV was further reduced at 12 months, this change lacked statistical significance. No statistically significant post-treatment changes were observed in SHIM, MSHQ-EjD 3-Item or Bother scores, or PSA. Mean pain score on the 10-point visual analog scale for procedural pain was 2.14 ± 0.69. Conclusions: Although limited by a lack of generalizability, our findings are consistent with previous studies that have shown EchoLaser TPLA to be a safe and effective in-office treatment for prostate-related voiding symptoms, with minimal discomfort and negligible impact on sexual function. Further studies with larger cohorts and extended follow-up are needed.
More Related Videos
06:04Surgical Treatment for Benign Prostatic Hyperplasia: Holmium Laser Enucleation of the Prostate HoLEP.
Published on: March 6, 2018
08:38Renal Capsule Xenografting and Subcutaneous Pellet Implantation for the Evaluation of Prostate Carcinogenesis and Benign Prostatic Hyperplasia
Published on: August 28, 2013
Related Concept Videos
Survey Safety
Self-Efficacy
Resistors In Series
In a series circuit, the...
Series Resonance
Household Wiring And Electrical Safety
Series and Parallel Capacitors
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...