Reduction of Liftoff Effect in Eddy Current Measurement of Electrical Conductivity Using Multi-Frequency Excitation
Jiajie Wu1, Yini Song1, Shukai Chen1
1School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
None:
Eddy current testing is a widely used technique for electrical conductivity measurement due to its advantage of contactless measurement. However, the results are easily influenced by liftoff change. In this study, a new solution to compensate for the liftoff effect in eddy current measurements of conductivity is proposed. By measuring the inductance of coils with different frequencies, the liftoff-conductivity solution sets at each frequency are obtained from an analytical model. By finding a common solution for all frequencies, we can obtain the liftoff of the probe and the conductivity of the specimen simultaneously, thus improving the accuracy and reliability of conductivity measurements. For a liftoff variation of 1.14 mm, the introduced measurement error is up to 70.46% for aluminum alloys without liftoff compensation. By finding the common solution for multiple frequencies, the error is reduced to less than 5.57%. The selection of the frequency and tolerance limit is also discussed for the proposed method.
Related Concept Videos
Eddy Currents
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Electrical Current
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Oxidation-Reduction Reactions
Conduction System of the Heart