Related Experiment Video
Updated: Jan 29, 2026

A Structured Rehabilitation Protocol for Improved Multifunctional Prosthetic Control: A Case Study
Published on: November 6, 2015
A Study on Rejecting Non-Target and Misclassified Motions for Robust Tactile-Sensor-Based Prosthetic Hand Control
Hayato Iwai1,2, Feng Wang3
1Graduate School of Engineering, Maebashi Institute of Technology, Maebashi 371-0816, Japan.
None:
Reliable motion classification is essential for practical prosthetic-hand control. Unintended activations caused by ambiguous motions, unknown motions, or non-target body movements can degrade controllability and compromise user safety. Mechanical-sensing approaches are attracting attention as alternatives or complements to surface electromyography, and tactile-sensor-based methods represent one such direction. However, despite extensive studies on prosthetic control, systematic investigations of computationally lightweight motion-rejection strategies remain limited. This study investigates rejection mechanisms to improve the robustness of polyvinylidene fluoride (PVDF) tactile-sensor-based prosthetic control. The proposed approach selectively withholds outputs for misclassified and non-target inputs. We compare three mechanisms: (1) one-class support vector machine (OCSVM) outlier detection, (2) entropy-based rejection using a multilayer perceptron (BPNN-Entropy), and (3) a parameter-free decision-consistency check for one-vs-rest support vector machines (SVMs) that withholds classification when the output sign pattern is inconsistent (one-vs-rest reject option (OvR-RO); proposed). Performance is evaluated for three sources of unintended activation: ambiguous target trials (retrospectively defined), unknown motions excluded from training, and non-target body movements. The results show that OvR-RO achieves a favorable balance between rejection rate and rejection precision for ambiguous motions, while maintaining responsiveness. Overall, explicitly rejecting misclassified and non-target motions is effective for enhancing robustness in tactile-sensor-based prosthetic control.
Related Concept Videos
Tactile and Chemical Senses
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Hand hygiene
Hand washing...
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Quantifying and Rejecting Outliers: The Grubbs Test
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...

