Related Experiment Video
Updated: Jan 29, 2026

Separation and Identification of Conventional Microplastics from Farmland Soils
Published on: March 21, 2025
A Cost-Effective Standardized Quantitative Detection Method for Soil Microplastics in Different Substrates
Xinlei Ling1,2, Yuting Gao1,2, Rongxiang Li1,2
1Institute of Eastern-Himalaya Biodiversity Research, Dali University, Dali 671003, China.
None:
Microplastics (MPs) are emerging pollutants with widespread global distribution, continuously accumulating in soils and posing risks of cross-media pollution. Current soil MP detection methods lack unified standards, suffering from high inter-laboratory variability and cost, which become key bottlenecks limiting data comparability and global microplastics pollution control. Here, we systematically reviewed soil MPs studies (2020-2024) and based on stepwise verification, we established a standardized, reproducible detection method: soil samples were dried at 80 °C for 12 h; density separation was performed in Erlenmeyer flasks with decantation, 10 s glass rod stirring, and 12 h settling, repeated five times; digestion was conducted using a 1:2 volume ratio of H2O2 to supernatant at 80 °C for 8 h; and MPs were quantified via stereo-microscopy combined with ImageJ. It should be noted that the use of NaCl limits the recovery of high-density polymers (e.g., PVC, PET), and the minimum detectable particle size is approximately 127 µm. The method was validated in sandy, loam, and clay soils, achieving an average recovery rate of 96.4%, with a processing time of 68 h and a cost of USD 9.77 per sample. In contrast to previous fragmented, non-standardized protocols, this workflow synergistically optimizes high recovery efficiency, cost-effectiveness, and broad applicability, offering a low-cost, efficient, and widely applicable approach for soil MPs monitoring, supporting data comparability across studies and contributing to global pollution assessment and the United Nations 2030 Sustainable Development Goals.
Related Concept Videos
The Soil Ecosystem
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Empirical Method to Interpret Standard Deviation
This rule is used widely in statistics to calculate the proportion of data values...
Calculating Standard Free Energy Changes
Standard Enthalpy of Formation
Standard Electrode Potentials

