Related Experiment Video
Updated: Jan 29, 2026

Detection of SARS-CoV-2 Receptor-Binding Domain Antibody using a HiBiT-Based Bioreporter
Published on: August 12, 2021
A Comparison of Flow Cytometry-based versus ImmunoSpot- or Supernatant-based Detection of SARS-CoV-2 Spike-specific
Georgia Stylianou1,2, Sharon Cookson2, Justin T Nassif3
1Faculty of Science and Environment, School of Geography and Natural Sciences, Northumbria University, Newcastle upon Tyne NE1 8ST, UK.
Background:
Memory B cells (Bmem) facilitate the generation of renewed and rapid antigen-specific antibody responses long after the initial antigen exposure, at a time when circulating serum antibodies may have declined. As the generation and/or recruitment of Bmem is at the core of most vaccination strategies, the assessment of antigen-specific Bmem is highly informative for forecasting and profiling the elicited B cell immune response.
Methods:
The two prevalent techniques used to detect antigen-specific Bmem cells at single-cell resolution are probe-based flow cytometry and B cell ImmunoSpot, while the measurement of B cell-derived antibodies in culture supernatants of stimulated B cells offers a semi-quantitative alternative. To the best of our knowledge, a direct side-by-side comparison of these assay systems has not yet been reported using the same starting PBMC material in a blinded fashion to test all three assays simultaneously.
Results:
These three assay systems were run in parallel to detect SARS-CoV-2 Wuhan-1 strain Spike-specific IgG+ Bmem in peripheral blood mononuclear cell (PBMC) samples obtained from well-defined cohorts comprising pre-COVID-19 era "naïve" individuals (negative controls), individuals shortly after recovery from a PCR-verified SARS-CoV-2 infection (positive controls), and a cohort of donor PBMCs isolated in 2024 (the experimental group). Each assay was able to discern Spike-exposed individuals from naïve , with ImmunoSpot suggesting superior sensitivity and specificity. ImmunoSpot and flow cytometry results were closely correlated.
Conclusions:
The study demonstrates that all three assays are suited for the detection of specific Bmem in antigen-primed individuals when such Bmem occur in the mid- to high-frequency range, and that they broadly concur. Strengths and weaknesses of the three test systems are discussed.
Related Concept Videos
Flow Cytometry
In...
Peripherally and Centrally Acting Muscle Relaxants: A Comparison
Centrally acting muscle relaxants can be further divided into spasmolytic and antispasmodic drugs. Spasmolytic...
Blood Flow
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Base Excision Repair
The first step of...
Weak Base Solutions

