Related Experiment Video
Updated: Jan 30, 2026

Author Spotlight: Hickman Catheter Use for Long-Term Vascular Access in a Preclinical Swine Model
Published on: March 31, 2023
Retrieval of a fractured radial access catheter from the axillary artery
Ryan T Kellogg1, Robert B Ferguson1, Pedro M Norat1
1Department of Neurosurgery, University of Virginia Medical Center, Charlottesville, VA, USA.
Abstract:
Radial access has become more common among interventionalists for neurointerventional procedures due to lower complication rates and patient comfort.1, 2 However, rare but serious complications such as catheter fracture and retention require recognition and investigation of advanced retrieval strategies.3 We present a two-stage case involving a patient in their 70s who initially underwent successful mechanical thrombectomy for left M1 occlusion. Hours later, new onset of neurological deficits led to repeat digital subtraction angiography via right radial access. During catheter withdrawal and after initial medical management of suspected vasospasm, the RIST guide catheter became entrapped and fractured within the axillary artery. Transfemoral access was used to retrieve the distal catheter fragment using a snare technique. Post-retrieval imaging confirmed vessel integrity, though ulnar artery occlusion led to ischemia requiring vascular surgery. This case illustrates a rare complication of radial access and highlights suspected novel technical considerations for retrieval, rescue planning, and catheter system selection.
Related Concept Videos
Retrieval
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...
ER Retrieval Pathway
The ER uses many checkpoints to prevent the entry of incorrectly folded or a resident protein as cargo onto a transport vesicle. These mechanisms...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

