IUGC: A benchmark of landmark detection in end-to-end intrapartum ultrasound biometry
Jieyun Bai1, Yitong Tang2, Xiao Liu3
1Department of Cardiovascular Surgery, The First Affiliated Hospital of Jinan University, Jinan University, Guangzhou, China; Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; School of Information Science and Technology, Jinan University, Guangzhou, China.
Abstract:
Accurate intrapartum biometry plays a crucial role in monitoring labor progression and preventing complications. However, its clinical application is limited by challenges such as the difficulty in identifying anatomical landmarks and the variability introduced by operator dependency. To overcome these challenges, the Intrapartum Ultrasound Grand Challenge (IUGC) 2025, in collaboration with the International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI), was organized to accelerate the development of automatic measurement techniques for intrapartum ultrasound analysis. The challenge featured a large-scale, multi-center dataset comprising over 32,000 images from 24 hospitals and research institutes. These images were annotated with key anatomical landmarks of the pubic symphysis (PS) and fetal head (FH), along with the corresponding biometric parameter-the angle of progression (AoP). Ten participating teams proposed a variety of end-to-end and semi-supervised frameworks, incorporating advanced strategies such as foundation model distillation, pseudo-label refinement, anatomical segmentation guidance, and ensemble learning. A comprehensive evaluation revealed that the winning team achieved superior accuracy, with a Mean Radial Error (MRE) of 6.53 ± 4.38 pixels for the right PS landmark, 8.60 ± 5.06 pixels for the left PS landmark, 19.90 ± 17.55 pixels for the FH tangent landmark, and an absolute AoP difference of 3.81 ± 3.12° This top-performing method demonstrated accuracy comparable to expert sonographers, emphasizing the clinical potential of automated intrapartum ultrasound analysis. However, challenges remain, such as the trade-off between accuracy and computational efficiency, the lack of segmentation labels and video data, and the need for extensive multi-center clinical validation. IUGC 2025 thus sets the first benchmark for landmark-based intrapartum biometry estimation and provides an open platform for developing and evaluating real-time, intelligent ultrasound analysis solutions for labor management.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...