The Effect of Anodization Parameters on the Aluminum Oxide Dielectric Layer of Thin-Film Transistors
Published on: May 24, 2020
Aluminum-copper layered double hydroxide-enabled electrochemiluminescence-multicolor dual-mode biosensor for
Zhenjie Zheng1, Mengqi Ma2, Liang Wang3
1College of Biological Science and Engineering, Fuzhou University, Fuzhou, Fujian, 350116, China; Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Key Laboratory of Analysis and Testing Technology for Food Safety and Health, College of Chemistry, Fuzhou University, 2 Xue Yuan Road, Fuzhou, Fujian, 350116, China.
Abstract:
Sepsis is a critical condition associated with substantial mortality, thus driving a pressing demand for rapid diagnostic approaches ranging from simple, readily deployable point-of-care testing (POCT) to highly sensitive laboratory-based detection methods. Heparin-binding protein (HBP), a neutrophil-derived protein, rises earlier and correlates more closely with disease severity than conventional biomarkers including procalcitonin and C-reactive protein, making it a promising biomarker for timely sepsis detection. To simultaneously meet these needs, we established a dual-mode biosensor that combines electrochemiluminescence (ECL) and multicolor for highly sensitive analysis of HBP. The sensing platform is constructed from an aluminum-copper layered double hydroxide (AlCu-LDH) scaffold conjugated with an HBP-specific aptamer and complementary DNA immobilized on magnetic beads (MBs). In the absence of HBP, the assembled AlCu-LDH-MBs probe suppresses ECL emission through ferrocene-mediated quenching while catalyzing efficient TMB oxidation to produce a strong multicolor response. Upon HBP binding, conformational switching induces probe disassembly, releasing AlCu-LDH and ferrocene from the duplex, thereby restoring ECL output while simultaneously attenuating the multicolor signal. Under optimized conditions, the biosensor achieved an ultralow detection limit of 0.023 pM in ECL mode with a linear range of 0.10 pM-10 nM, whereas the multicolor mode showed a detection limit of 0.43 nM and exhibited linearity across 0.50-10 nM, accompanied by an intuitive multicolor transition from gray to purple. Notably, this strategy avoids tedious electrode surface modification and relies on magnetic separation to regulate signal generation, thereby simplifying operation while offering a sensitive and practical tool for early sepsis diagnosis that bridges laboratory-grade analysis with instrument-free POCT.
Related Concept Videos
Factors Affecting Protein-Drug Binding: Protein-Related Factors
The physicochemical properties of a drug play a significant role in its ability to bind to proteins. Lipophilic drugs, which dissolve in fats, oils, and lipids, can be...
The Equilibrium Binding Constant and Binding Strength
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ligand Binding Sites
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
Fixing Double-strand Breaks
Drug Distribution: Plasma Protein Binding