Related Experiment Video
Updated: Jan 30, 2026

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Graphene-enhanced non-Hermitian Thue-Morse metamaterial sensor exploiting exceptional point for cancer biomarker
Ali Mohammadpour1, Ali Soltani Vala2, Jamal Barvestani2
1Faculty of Physics, University of Tabriz, Tabriz, 51666-16471, Iran. a.m.pour@tabrizu.ac.ir.
Abstract:
We present a one-dimensional photonic crystal biosensor based on a Thue-Morse quasi-periodic structure incorporating parity-time (PT) symmetry and exceptional point (EP) engineering for enhanced cancer detection. By integrating alternating porous silicon gain-loss layers with graphene nanolayers, the proposed design achieves strong optical confinement and pronounced resonance sharpening near EP conditions. A systematic parametric study identified the optimal graphene chemical potential and relaxation time as 0.408 eV and 0.5 ps, respectively, leading to a maximum sensitivity of 1054 nm/RIU and a minimum detection limit of 9.875 × 10- 4 RIU. Moreover, the analysis reveals that increasing the number of graphene layers results in a progressive enhancement in sensitivity accompanied by a reduction in the optimal porosity percentage, highlighting the strong influence of graphene-induced field confinement on device performance. These results surpass those of conventional one-dimensional biosensors, demonstrating the combined advantages of PT symmetry and graphene-assisted field enhancement. Fabrication tolerance analysis confirmed the structural robustness, underscoring its potential for practical implementation. Overall, the findings establish PT-symmetric Thue-Morse photonic crystals as a versatile platform for ultra-sensitive, label-free biomedical sensing, paving the way for next-generation optical diagnostic technologies.
Related Concept Videos
Exceptions to the Octet Rule
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement
Bioavailability Enhancement: Drug Stability Enhancement and GI Retention
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...

