Abstract:
Background Radiographically occult hip and pelvic fractures are relatively common in older adults after low-energy trauma, and delayed or missed diagnosis is associated with worse outcomes. MRI is the preferred modality for detection, while CT remains important for fracture delineation, surgical planning, and use in patients with MRI contraindications. However, using both modalities increases cost, imaging time, and strain on imaging services. MRI-based pseudo-CT (pCT) methods derived from 3D T1-volumetric interpolated breath-hold examination (VIBE) data have shown promise in other settings, but their role in evaluating occult hip and pelvic fractures has not yet been explored. This study aimed to explore the clinical performance and usability of MR-based pCT for detecting and characterizing radiographically occult hip and pelvic fractures. Specifically, the study aimed to compare pCT and conventional CT in terms of fracture detection, fracture characterization, diagnostic confidence, and interobserver agreement. Methodology This retrospective study included 22 patients (18 men, 4 women; mean age = 75.7 ± 10.6 years) with a total of 12 radiographically occult hip and pelvic fractures. All patients underwent the same-day MRI and CT imaging, including 3D T1-VIBE sequences processed with grayscale inversion to generate pCT images. Two radiologists independently evaluated both imaging modalities in a blinded and randomized fashion for fracture presence, location, and characteristics. Diagnostic confidence was assessed using a five-point scale. The reference standard was established by two senior radiologists using all available clinical and imaging data. Statistical analyses were performed to evaluate diagnostic performance, diagnostic confidence, and interobserver agreement. Results pCT showed diagnostic performance not inferior to CT for both readers (R1 and R2) (predefined non-inferiority Δ = -10%; R1 Δ = +18.2% (95% confidence interval (CI) = -3.7% to +18.2%), p = 0.0026; R2 Δ = +27.3% (95% CI = 2.2% to +27.3%), p = 0.0010). pCT detected all CT-apparent fractures and showed perfect concordance with CT in fracture localization and characterization. There was no statistically significant difference in diagnostic performance between pCT and CT, although pCT for both readers showed a trend toward higher sensitivity (pCT vs. CT; R1 90.0% vs. 60.0%; R2 100% vs. 60.0%), lower specificity (pCT vs. CT; R1 91.7% vs. 100%; R2 83.3% vs. 100%), and higher accuracy (pCT vs. CT; R1 90.9% vs. 81.8%; R2 90.2% vs. 81.8%). There was no significant difference in diagnostic confidence between the two modalities, with pCT demonstrating a trend toward slightly higher confidence when ruling in fractures and slightly lower confidence when ruling out. Interobserver agreement was perfect for CT (κ = 1.00) and moderate for pCT (κ = 0.55). Conclusions Compared with conventional CT, 3D T1-VIBE MR-based pCT demonstrated diagnostic performance that was not inferior for detecting radiographically occult hip and pelvic fractures, with perfect concordance in fracture characterization. pCT enables comprehensive fracture assessment within a single MRI examination, and our findings suggest that pCT has the potential to serve as a viable alternative to CT, enabling a "one-stop-shop" imaging approach in appropriate clinical scenarios.
Insights
MRI-based pseudo-CT (pCT) shows non-inferior diagnostic performance for detecting occult hip and pelvic fractures compared to conventional CT. This imaging approach may offer a "one-stop-shop" solution, improving efficiency in fracture assessment.
Area of Science:
- Radiology
- Medical Imaging
- Orthopedics
Background:
- Occult hip and pelvic fractures in older adults are common after low-energy trauma.
- Delayed diagnosis of these fractures is linked to poorer patient outcomes.
- MRI is preferred for detection, while CT aids delineation and surgical planning, but using both increases costs and service strain.
Purpose of the Study:
- To explore the clinical performance and usability of MRI-based pseudo-CT (pCT) for detecting and characterizing radiographically occult hip and pelvic fractures.
- To compare pCT with conventional CT regarding fracture detection, characterization, diagnostic confidence, and interobserver agreement.
Main Methods:
- Retrospective study of 22 patients with 12 occult hip/pelvic fractures, all undergoing same-day MRI and CT.
- 3D T1-VIBE MRI sequences were used to generate pCT images.
- Two blinded radiologists independently evaluated both modalities for fracture presence, location, and characteristics, assessing diagnostic confidence on a 5-point scale.
Main Results:
- pCT demonstrated non-inferior diagnostic performance compared to CT for both readers.
- pCT detected all CT-apparent fractures and showed perfect concordance with CT in localization and characterization.
- While not statistically significant, pCT showed trends toward higher sensitivity and accuracy, with no significant difference in diagnostic confidence.
Conclusions:
- MRI-based pCT is not inferior to conventional CT for detecting radiographically occult hip and pelvic fractures.
- pCT allows comprehensive fracture assessment within a single MRI examination.
- pCT shows potential as a viable alternative to CT, enabling a "one-stop-shop" imaging approach.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Breathing
Reconstruction of Signal using Interpolation