Related Experiment Video
Updated: Jan 31, 2026

Constructing and Visualizing Models using Mime-based Machine-learning Framework
Published on: July 22, 2025
Differentiation of focal liver lesions in contrast-enhanced ultrasound using a heuristic-guided hybrid
Keisuke Nakajima1, Naohisa Kamiyama2, Katsutoshi Sugimoto3
1Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
Purpose:
Sonazoid contrast-enhanced ultrasound (CEUS) offers valuable diagnostic information on hepatic lesions, but it is time-consuming. In this study, we investigated a novel composite machine-learning framework that integrates heuristic knowledge and model-specific classification to differentiate liver lesions using only the first 2 min of CEUS imaging.
Methods:
CEUS images from 232 patients with 232 focal liver lesions (benign: 61, hepatocellular carcinoma [HCC]: 104, non-HCC malignancies [ML]: 67) were analyzed. For each case, six frames from injection to peak enhancement and static images at 1 and 2 min post-injection were used. Two deep learning models were developed: Model 1 classified heterogeneous enhancement patterns into "benign," "HCC," "ML," or "Uniform" (homogeneous). Model 2 further classified "Uniform" cases into three diagnostic categories. Lesion brightness values were incorporated as input features. The artificial intelligence (AI) mode was also evaluated by observer study of three hepatologists using the area under the receiver operating characteristic curve (AUC).
Results:
The composite model was evaluated on 58 independent test cases, achieving classification accuracy of 81.8% for benign, 93.5% for HCC, and 68.8% for ML, with an overall accuracy of 84.5%. Binary classification (benign vs. malignant) yielded 97.9% sensitivity, 94.8% specificity, and 94.8% overall accuracy. For discrimination between benign and malignant, the mean AUC for the three observers was significantly improved with AI output, where the difference in AUC (95% confidence interval) was 0.095 (0.0197, 0.1703) (P = 0.013).
Conclusions:
The proposed AI-based framework enables accurate liver lesion classification using early phase CEUS, eliminating the need for Kupffer-phase imaging in many cases.
More Related Videos
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
Related Concept Videos
The Availability Heuristic
The Representativeness Heuristic
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
The Anchoring-and-Adjustment Heuristic
Heuristics
People often rely on heuristics when faced with an overload of information, limited time, low importance of the decision, limited information, or when a heuristic readily comes to mind. For...
Hybrid Zones