Related Experiment Video
Updated: Jan 31, 2026

Bergmeyer Glucose Quantification for Microbiological Samples
Published on: January 17, 2025
Comparison of glucose concentration measured in samples collected with different anticoagulants and analyzed using 2
Anay D Ravelo1, Megan Ruch1, Isaac J Salfer2
1Department of Veterinary Population Medicine, University of Minnesota, Saint Paul, MN 55108.
None:
Sodium fluoride (NaF), K2-EDTA, and lithium heparin are common anticoagulants used during collection of bovine blood for glucose concentration. Whereas NaF is considered the best anticoagulant for preservation of glucose, other anticoagulants are used because of their ability to simultaneously preserve other metabolites frequently measured in dairy science experiments. To simplify sample collection and reduce the need for multiple tubes, it may be possible to use tubes with anticoagulants other than NaF, provided they yield comparable glucose concentrations. Additionally, blood glucose concentrations are commonly analyzed using a peroxidase and glucose oxidase (PGO) colorimetric assay with a standard plate reader, but the use of a semi-automated chemistry analyzer with a hexokinase (HK) enzymatic reaction method is becoming more common in dairy research because it is also available and easy to use. Thus, the objective of this study was to determine the influence of the use of NaF, dipotassium EDTA (K2-EDTA), or lithium heparin (Li-Hep) as anticoagulants on glucose quantification, using both the PGO and HK enzymatic reaction methods. Blood samples from 20 fresh cows (7 ± 3 DIM) were collected into NaF, K2-EDTA, or Li-Hep plasma tubes on a commercial dairy farm (n = 60 samples). All samples were analyzed using both the PGO method, performed on a 96-well plate with a colorimetric microplate reader, and the HK method, conducted on a semi-automated chemistry analyzer. It was observed that in both methods, samples collected into NaF tubes had less glucose quantified compared with samples collected into K2-EDTA and Li-Hep tubes. Additionally, it was observed that in samples quantified with the HK method, the glucose concentrations were lower than when those samples were quantified with the PGO method. Thus, the K2-EDTA and Li-Hep anticoagulant could be used for glucose quantification to avoid cumbersome collection of several tubes, but results must be reviewed with caution as concentrations would be higher compared with those quantified with NaF. This observation is also conserved when quantifying glucose using the PGO and HK methods.
More Related Videos
06:28A Simple Flow Cytometric Method to Measure Glucose Uptake and Glucose Transporter Expression for Monocyte Subpopulations in Whole Blood
Published on: August 12, 2016
10:35Extracellular Glucose Depletion as an Indirect Measure of Glucose Uptake in Cells and Tissues Ex Vivo
Published on: April 6, 2022
Related Concept Videos
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Glucose Transporters
Facilitated diffusion-glucose transporters (GLUTs) are encoded by the solute-linked carrier (SLC) family 2, subfamily A gene family, or SLC2A. The 14 GLUT protein members are distributed into three classes:
Glucose Absorption Into the Small Intestine
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...
Drug Concentrations: Measurements
Plasma...