Cobalt-Catalyzed γC-H Functionalization of Alcohols via Olefin-Tethered Radical Relay

Phong Dam1, Kosala N Amarasinghe1, Chenyang Wang1

  • 1Leibniz Institute for Catalysis e.V., Albert-Einstein-Str. 29a, 18059 Rostock, Germany.

JACS Au
|January 30, 2026
PubMed
Abstract

Related Concept Videos

Acid-Catalyzed Dehydration of Alcohols to Alkenes02:35

Acid-Catalyzed Dehydration of Alcohols to Alkenes

In a dehydration reaction, a hydroxyl group in an alcohol is eliminated along with the hydrogen from an adjacent carbon. Here, the products are an alkene and a molecule of water. Dehydration of alcohols is generally achieved by heating in the presence of an acid catalyst. While the dehydration of primary alcohols requires high temperatures and acid concentrations, secondary and tertiary alcohols can lose a water molecule under relatively mild conditions.
23.9K
Radical Oxidation of Allylic and Benzylic Alcohols01:21

Radical Oxidation of Allylic and Benzylic Alcohols

Activated manganese(IV) oxide can selectively oxidize allylic and benzylic alcohols via a radical intermediate mechanism. Primary allylic alcohols are oxidized to aldehydes, while secondary allylic alcohols yield ketones. The redox reaction of potassium permanganate with an Mn(II) salt such as manganese sulfate (under either alkaline or acidic conditions), followed by thorough drying, yields the oxidizing agent: activated MnO2. While MnO2 is insoluble in the solvents used for the reaction, the...
2.9K
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
612
Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
535
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
767
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
452