From batch to flow plasmon catalysis: revealing mass transport limits in Au@Pd nanocatalysts for Suzuki coupling

Mariia Erzina1, Daria Votkina2, Elena Miliutina1

  • 1Department of Solid-State Engineering, University of Chemistry and Technology, Technicka 5, Prague 166 28, Czech Republic.

Nanoscale
|January 30, 2026
PubMed

Related Concept Videos

Catalysis02:50

Catalysis

The presence of a catalyst affects the rate of a chemical reaction. A catalyst is a substance that can increase the reaction rate without being consumed during the process. A basic comprehension of a catalysts’ role during chemical reactions can be understood from the concept of reaction mechanisms and energy diagrams.
30.5K
Limiting Reactant02:27

Limiting Reactant

The relative amounts of reactants and products represented in a balanced chemical equation are often referred to as stoichiometric amounts. However, in reality, the reactants are not always present in the stoichiometric amounts indicated by the balanced equation.
70.0K
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models00:57

Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models

Physiological pharmacokinetic models, often called flow-limited or perfusion models, typically assume a swift drug distribution between tissue and venous blood, creating a rapid drug equilibrium. This premise is based on the idea that drug diffusion is extremely fast, and the cell membrane presents no barrier to drug permeation. In this scenario, where no drug binding occurs, the drug concentration in the tissue equals that of the venous blood leaving the tissue. This greatly simplifies the...
350
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.4K
Facilitated Transport01:19

Facilitated Transport

The chemical and physical properties of plasma membranes cause them to be selectively permeable. Since plasma membranes have both hydrophobic and hydrophilic regions, substances need to be able to transverse both regions. The hydrophobic area of membranes repels substances such as charged ions. Therefore, such substances need special membrane proteins to cross a membrane successfully. In  facilitated transport, also known as facilitated diffusion, molecules and ions travel across a...
147.9K
PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
653