Osteoporosis prediction using lumbar CT Hounsfield units: comparative performance and clinical implications of seven
Akihiko Hiyama1, Daisuke Sakai2, Hiroyuki Katoh2
1Department of Orthopaedic Surgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan. a.hiyama@tokai.ac.jp.
Purpose:
This study aimed to evaluate the utility of L1-L4 average Hounsfield Unit (HU) values from lumbar spine computed tomography (CT) in predicting osteoporosis using multiple machine learning (ML) models.
Methods:
We retrospectively analyzed 172 patients (≥ 50 years) who underwent lumbar spine surgery and received preoperative CT and dual-energy X-ray absorptiometry (DXA) within 3 months. Osteoporosis was defined as a T-score < - 2.5 at either the lumbar spine or femoral neck. The L1-L4 average HU value was used as the sole input variable to develop seven supervised ML models. Model performance was compared using accuracy, precision, recall, F1 score, and area under the receiver operating characteristic curve (AUC), and HU-based thresholds for osteoporosis screening were explored.
Results:
Of 172 patients, 59 (34.3%) were classified as having osteoporosis. The osteoporosis group showed significantly lower L1-L4 HU values than the non-osteoporosis group (105.1 ± 47.5 vs. 140.1 ± 61.3, p < 0.01). Among the models, K-nearest neighbors (KNN) achieved the most balanced diagnostic performance (accuracy: 0.714 ± 0.048; F1 score: 0.466 ± 0.073). Logistic Regression and Naive Bayes showed the highest AUCs (0.785 ± 0.096 and 0.777 ± 0.098, respectively) but limited recall, whereas Support Vector Machine demonstrated moderate performance. Tree-based models yielded comparatively lower discriminatory ability. Optimal HU ranges for identifying high osteoporosis risk generally converged around 90-130 HU.
Conclusions:
ML models using L1-L4 HU values can aid in osteoporosis screening. KNN provided the most robust and balanced diagnostic performance, while Logistic Regression and SVM offered stable threshold-based classification. These findings support the utility of CT-based ML approaches in preoperative spinal surgery settings, particularly where DXA is unavailable or limited.
More Related Videos
06:19Constructing and Visualizing Models using Mime-based Machine-learning Framework
Published on: July 22, 2025
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
Related Concept Videos
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Measurement: Standard Units
Predicting Molecular Geometry
Machines
A free-body diagram of the...
