Related Experiment Video
Updated: Feb 1, 2026

Author Spotlight: Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon
Published on: February 3, 2023
In-situ sensitivity calibration for a fiber Bragg grating Fabry-Perot interferometric pressure sensor in a side-hole
Abstract:
We demonstrate an in-situ pressure-sensitivity calibration method for a fiber Bragg grating Fabry-Perot interferometric pressure sensor inscribed in a side-hole fiber. The calibration of pressure sensitivity is achieved by applying pressure internally to the sensor through the side holes in the fiber cladding. Both simulations and experiments confirm that the pressure sensitivity under internal pressurization closely matches that under external loading, enabling direct in-situ calibration. The sensor system maintains a resolution better than 1 psi up to 300°C and good repeatability. We also discuss exploiting the method for resolving measurement ambiguity arising from the rotation of the principal polarization axes of the sensor.
Related Concept Videos
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...
Fiber Reinforced Concrete
Types of Skeletal Muscle Fibers
Fast-twitch fibers
Fast-twitch fibers, or Type II fibers, are designed for quick, powerful bursts of speed and strength. They reach peak tension within approximately 0.01 seconds following stimulation. Characterized by a large diameter and densely packed myofibrils, these fibers contain...
Formation of Muscle Fibers from Myoblasts
Muscle progenitor cells (MPCs) are formed from the myotomes. MPCs express genes that encode the transcription factors Pax3 and Pax7. Along with Pax 3/7, other transcription...
Connective Tissue Fibers and Ground Substance