Related Experiment Video
Updated: Feb 1, 2026

Bio-inspired Polydopamine Surface Modification of Nanodiamonds and Its Reduction of Silver Nanoparticles
Published on: November 14, 2018
Polydopamine-assisted Cd/Cu dual-ion immobilization on titanium surface for the application of antibacterial surgical
Wenyi Yu1, Chengming Zhang1, Hui Xia1
1School of Materials Science and Engineering, Jiamusi University, Jiamusi 154007 Heilongjiang Province, People's Republic of China.
Abstract:
Titanium and its alloys have excellent mechanical and biocompatibility features, which are commonly utilized in the production of surgical instruments, such as scalpels, surgical tweezers, needle holders, etc. However, lacking antibacterial ability, titanium materials are susceptible to bacterial infection, which hinders the success of surgical operations. Medical titanium substrates were modified using polydopamine (PDA) coatings in this study, followed by cadmium (Cd) and copper (Cu) ions loaded into the PDA coating to endow titanium surgical instruments with antibacterial properties. The surface topography, chemical state, ion release, and other features of the specimen were analyzed. Additionally, the minimum inhibitory concentration and minimum bactericidal concentration of Cd and Cu ions againstStaphylococcus aureus(S. aureus) andEscherichia coli(E. coli) were quantitatively determined through serial dilution methodology. The antibacterial features of embellished substrates were investigated against bothS. aureusandE. coli. The results demonstrated that the dual-ions (Cd/Cu) modified coating exhibits a reduction in ion release compared to the single ion loaded coatings, with Cd ions demonstrating a 95.13% reduction. Furthermore, the antimicrobial ability of the dual-ions (Cd/Cu) modified coating againstS. aureusandE. coliwas superior to the PDA coating, with antibacterial rates of 99.89% and 92.04%, respectively. The Cd/Cu co-modified coating achieves a balance between low ion release and excellent antibacterial activity, providing insights for metal ion loading and the antibacterial modification of titanium surfaces.
More Related Videos
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Common Ion Effect
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier