Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
Influence of CT harmonization in longitudinal radiomics for NSCLC immunotherapy response prediction
Benito Farina1, Gonzalo Vegas-Sánchez-Ferrero2, Ana Delia Ramos-Guerra1
1Biomedical Image Technologies, ETSI Telecomunicación, Universidad Politécnica de Madrid, Madrid, 28040, Madrid, Spain; Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Instituto de Salud Carlos III, Madrid, Madrid, Spain.
Abstract:
This study investigates the variability of radiomic features in longitudinal CT scans from a multi-institutional NSCLC cohort and introduces a harmonization pipeline to improve predictive modeling of immunotherapy response. Baseline and follow-up CT scans from NSCLC patients treated with anti-PD-1/PD-L1 agents were analyzed, with two institutions combined for model training and internal testing, and a third institution serving as an external test set. To address variability from imaging parameters-such as scanner manufacturer, slice thickness, and noise-we applied image harmonization followed by feature harmonization using NestedComBat. This approach substantially reduced feature dependence on acquisition confounders (from 78.8% to 12.8%) and improved feature robustness across institutions. We further assessed the temporal consistency of radiomic features across longitudinal scans using the intraclass correlation coefficient (ICC). Image harmonization yielded the largest gains in stability (mean ΔICC = +0.021, p < 0.001), while the combined approach also enhanced longitudinal reliability (ΔICC = +0.014, p < 0.001). Finally, harmonization improved predictive performance for 6-month immunotherapy response, increasing the AUC from 0.695 to 0.768 in the internal test and from 0.692 to 0.802 in the external test. These results demonstrate that combining image- and feature-level harmonization enhances the robustness and temporal consistency of radiomic features, potentially supporting more reliable and generalizable predictive modeling across diverse datasets and clinical settings.
Related Concept Videos
Longitudinal Research
Harmonic Mean
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
Chronopharmacokinetics: Circadian Rhythms and Influence on Drug Response
The time of drug administration is an important factor to consider, as it can influence the toxic dose of a drug. For example, a study conducted by Prins et al. in 1997 examined the effects of the timing of...
Tumor Immunotherapy
Predicting Molecular Geometry
Longitudinal Studies