Development and preliminary evaluation of a transducer guiding system for hand ultrasound: With a focus on
Mu-Ting Wang1, Yu-Chen Lin2, Chieh-Hsiang Hsu3
1Department of Biomedical Engineering, College of Engineering, National Cheng Kung University, Tainan City, Taiwan.
Abstract:
Various strategies have been proposed to reduce operator-dependent variability in musculoskeletal ultrasound, including mechanical stabilization techniques. However, their effects on image reproducibility and transducer handling remain unclear in anatomically complex regions such as hand. This two-phase study aimed to (1) develop and validate a transducer guiding system for hand ultrasound and (2) evaluate its influence on image reproducibility and operational stability through image-based analyses. In Phase I, test-retest reliability of the guiding system was examined by repeatedly measuring soft-tissue thickness in 30 healthy participants. Intraclass Correlation Coefficients (ICC) ranged from 0.766 to 0.948, demonstrating good to excellent reliability. In Phase II, 16 ultrasound users acquired images under handheld and guiding-system-assisted conditions based on predefined reference images. Image reproducibility was evaluated using Normalized Cross-Correlation (NCC) and ICC, while operational stability was assessed via cosine similarity derived from M-mode segments during the pre-capture period, with group comparisons performed using the Wilcoxon signed-rank test. Novice users showed substantial ICC improvement when using the guiding system (0.487-0.681), approaching the consistency observed in experienced users. Both novice and experienced groups displayed higher NCC and cosine similarity values with the guiding system, indicating improved reproducibility and operational stability. Overall, the guiding system enhanced image outcomes by providing standardized positioning and mechanical stabilization. These findings highlight its potential to improve consistency in hand ultrasound assessments and serve as a supportive tool for novice ultrasound training. The results further demonstrate the feasibility of mechanical stabilization in reducing operator-related variability and enhancing image consistency in hand ultrasound examinations.
More Related Videos
05:54MRI-guided Focused Ultrasound Thalamotomy for Patients with Medically-refractory Essential Tremor
Published on: December 13, 2017
08:02A High-Throughput Image-Guided Stereotactic Neuronavigation and Focused Ultrasound System for Blood-Brain Barrier Opening in Rodents
Published on: July 16, 2020
Related Concept Videos
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Hand hygiene
Hand washing...
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Operational Amplifiers
Real Number Operations