Purpose:
The purpose of this systematic review and multilevel meta-analysis was to compare short-term functional outcomes, pain relief, and complication rates between open and endoscopic gluteal tendon repair, expressed as functional improvement normalized to minimal clinically important difference (MCID) units. The hypothesis was that endoscopic repair would provide comparable clinical efficacy with a lower complication rate compared with open repair.
Methods:
PubMed, Embase, CENTRAL and Epistemonikos were searched to 15 October 2025. Eligible primary studies reporting postoperative or change outcomes were synthesized with a frequentist multilevel random-effects model (inverse variance, restricted maximum likelihood estimation, Hartung-Knapp adjustment).
Results:
Thirty-four studies (1278 patients; 1283 hips) met criteria. Postoperative functional MCID (27 studies; n = 1005): overall 9.01 (95% confidence interval [CI]: 8.11-9.91; I2 = 100%; τ2 = 5.2); open 9.09 (8.12-10.06; six studies; n = 398) versus endoscopic 8.96 (8.02-9.90; 17 studies; n = 607); no subgroup difference (p = 0.63). Change in functional MCID (21 studies; n = 718): overall 3.33 (2.86-3.81; I2 = 83%; τ2 = 0.9); open 3.10 (2.39-3.81; nine studies; n = 290) versus endoscopic 3.52 (2.89-4.15; 12 studies; n = 428); no difference (p = 0.36). Postoperative pain MCID (19 studies; n = 867): overall 1.71 (1.27-2.16; I2 = 98%; τ2 = 0.9); open 1.58 (1.03-2.13; nine studies; n = 349) versus endoscopic 1.81 (1.31-2.32; 11 studies; n = 518); no difference (p = 0.38). Change in pain MCID (19 studies; n = 798): overall -1.99 (-2.74 to -1.24; I2 = 99%; τ2 = 2.5); open -1.82 (-2.96 to -0.69; nine studies; n = 349) versus endoscopic -2.12 (-3.18 to -1.09; 11 studies; n = 449); no difference (p = 0.68). Overall complications (25 studies; n = 804): 58/804 (0.07; 95% CI: 0.05-0.11; I2 = 53%; τ2 = 0.8); open 33/371 (0.08; 0.04-0.16) versus endoscopic 25/433 (0.07; 0.04-0.12); no difference (p = 0.70).
Conclusion:
Open and endoscopic gluteal tendon repair provide clinically meaningful short-term improvements in function and pain, with no relevant differences in efficacy when interpreted using MCID units. These findings support both techniques in clinical practice and favour endoscopic repair when available due to its less invasive nature.
Level Of Evidence:
Level III, systematic review and meta-analysis of predominantly Level III studies.
More Related Videos
Related Concept Videos
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Overview of DNA Repair
Chemically...
Base Excision Repair
The first step of...
Nucleotide Excision Repair
Nucleotide Excision Repair
Cells are regularly exposed to mutagens—factors in the environment that can damage DNA and generate mutations. UV radiation is one of the most common mutagens and is estimated to introduce a significant number of changes in DNA. These include bends or kinks in the structure, which can block DNA replication or transcription. If these errors are not fixed, the damage can cause mutations, which in turn can result in cancer or disease depending on which sequences are...