Dual-Mode Lateral Flow Assay for Simultaneous Quantification of Antibiotic and Bacteria
Zishan Xu1,2, Ting Wu2, Bingjie Wang1,2
1School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, Guangdong 510515, China.
None:
Simultaneous detection of chemical and biological contaminants in complex samples remains a major analytical challenge. Here, we present a dual-mode lateral flow assay (LFA) based on magnetic-SiO2-fluorescent probes (Fe@Si@QDs) possessing dual "enrichment-signal amplification" functions. The platform integrates both sandwich and competitive formats, enabling ultrasensitive and quantitative detection of a representative antibiotic (gentamicin) and pathogen (Escherichia coli O157) on a single test strip. The Fe@Si@QDs probe incorporates a SiO2 interlayer between the 180 nm Fe3O4 core and outer quantum dots (QDs), effectively suppressing fluorescence inner-filter effects from the magnetic core while enhancing probe dispersibility and chromatographic mobility. Antibody-functionalized Fe@Si@QDs facilitate efficient cocapture of both microorganisms and antibiotics, enabling precise quantitative detection through fluorescence signal enhancement on the microbial test line and attenuation on the small-molecule test line. The developed LFA method achieved detection limits of 36 cfu/mL for E. coli O157 (E. coli O157) and 2.05 pg/mL for gentamicin (GEN), offering at least a 500-fold sensitivity improvement over conventional colorimetric-LFA methods. Validation with real environmental and food samples demonstrated excellent reliability and stability, underscoring the platform's broad applicability for on-site, household, and laboratory use.
More Related Videos
Related Concept Videos
Antibiotic Selection
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Lateralization
Modes of Standing Waves - I
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....