Related Experiment Video
Updated: Feb 2, 2026

Implantation of Total Artificial Heart in Congenital Heart Disease
Published on: July 18, 2014
Implications of Early and Late Pacemaker Implantation After Heart Transplantation
Matthew Dean1, Cesar Rodrigo Zoni2, Garrett Frady3
1Internal Medicine Residency, Virginia Commonwealth University, Richmond, Virginia.
Background:
Variables associated with permanent pacemaker (PPM) implantation after heart transplantation and the relationship between PPM placement and mortality are poorly understood. This study evaluates factors contributing to PPM insertion and subsequent mortality rates, with emphasis on the timing of implantation.
Methods:
The United Network for Organ Sharing registry was queried for adult heart transplant recipients from 2010 to 2023. A multistate model was constructed, assessing the probability of 3 transitions: transplant to pacemaker, pacemaker to death, and transplant to death. Multivariable Cox proportional hazards models evaluated clinical factors influencing transitions, including early (≤30 days) and late (>30 days) PPM implantation.
Results:
Of the 30,566 patients included in the model, 1698 (5.6%) received a PPM, with most occurring in the late period (n = 1354 [79.7%]). At 5 years, late PPM recipients had a significantly higher cardiac allograft vasculopathy burden (30.3%) than non-PPM (14.9%) and early PPM (15.7%) recipients. Factors associated with increased probability of PPM insertion included antiarrhythmic use (hazard ratio [HR], 1.19 [1.02-1.40]), ischemia time (HR, 1.08 per hour [1.03-1.12]), and older donor age (HR, 1.02 per year [1.01-1.02]). Bicaval anastomosis decreased the likelihood of PPM insertion (HR, 0.69 [0.62-0.78]). Factors associated with increased probability of transition from PPM to death included late PPM insertion (HR, 2.58 [1.93-3.46]), recipient diabetes (HR, 1.29 [1.05-1.58]), and ischemic cardiomyopathy (HR, 1.25 [1.01-1.54]).
Conclusions:
Longer ischemia time and antiarrhythmic use increased PPM likelihood. Late PPM recipients had a significantly higher probability of transitioning from implantation to death, warranting further investigation into contributing factors and its relationship with cardiac allograft vasculopathy.
Related Concept Videos
Anatomy of the Heart
Anatomy of the Heart
The heart has three layers: the innermost endocardium, the muscular myocardium, and the outer epicardium, all working together for optimal cardiac function.
Chambers of the Heart
The heart is made up of four...
Overview of the Heart
The heart's structure...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Tissue Transplantation
The Biology of Tissue Transplantation
The biology of tissue transplantation hinges on the Major Histocompatibility Complex (MHC) molecules. These molecules...

