Related Experiment Video
Updated: Feb 4, 2026

Sample Preparation in Quartz Crystal Microbalance Measurements of Protein Adsorption and Polymer Mechanics
Published on: January 22, 2020
A novel molecularly imprinted quartz crystal microbalance sensor for fenamiphos determination based on boron-sulphur
Şule Yıldırım Akıcı1, Ahmet Düzel2, Ülkü Melike Alptekin3
1Department of Nutrition and Dietetics, Faculty of Health Sciences, Hasan Kalyoncu University, Gaziantep, 27010, Turkey.
Abstract:
Fenamiphos (FEN), an organophosphorus insecticide, has been frequently used in recent years to control many nematode pests. Nonetheless, its serious adverse effects have currently raised concerns about human health and the ecological environmental safety. In the present study, a novel flow injection-type portable quartz crystal microbalance (QCM) sensor based on a boron and sulphur co-doped ultra-thin graphitic carbon nitride (g-C3N4)-incorporated Cu-MOF (BS-g-C3N4-CuMOF) nanocomposite was developed and used for FEN determination in apple juice samples. For this, the BS-g-C3N4-CuMOF nanocomposite was prepared via an in situ solvothermal procedure with high synthesis yields. Then, a molecularly imprinted QCM sensor based on the BS-g-C3N4-CuMOF nanocomposite was prepared using methacryloylamidoglutamic acid (MAGA) as a monomer and N,N'-azobisisobutyronitrile (AIBN) as an initiator via UV polymerization. This QCM sensor revealed a linearity of 1.0 × 10-9-2.0 × 10-8 mol L-1 with a limit of detection (LOD) of 3.3 × 10-10 mol L-1 for the FEN molecule, suggesting the successful development of the sensitive molecularly imprinted QCM sensor. The prepared sensitive molecularly imprinted QCM sensor was applied to an apple juice sample with high recovery. Moreover, the high selectivity of the molecularly imprinted QCM sensor was confirmed in the presence of competing agents in the apple juice sample, and the prepared QCM sensor was shown to detect FEN at least 5 times more selectively than the other competing agents. In addition, the proposed sensor was validated in correlation with standard high-end measurements like GC-MS, and there was no significant difference between the results of the proposed sensor and GC-MS method. The low relative standard deviation (RSD) value of 20 independent QCM signals also suggested the high reproducibility of the QCM sensor. Finally, its high repeatability and reusability are presented herein in detail.
More Related Videos
09:46Adsorption Device Based on a Langatate Crystal Microbalance for High Temperature High Pressure Gas Adsorption in Zeolite H-ZSM-5
Published on: August 25, 2016
08:22Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
Related Concept Videos
Imprinting
Genomic Imprinting and Inheritance
The expression of some genes depends on which parent passed the gene to the offspring, through a phenomenon known as...
Molecular Shape and Polarity
Molecular Orbital Theory II
The Carbon Cycle
Predicting Molecular Geometry