Related Experiment Video
Updated: Feb 4, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Senile thoracolumbar tuberculosis with kyphosis and severe osteoporosis treated with polymethylmethacrylate-augmented
B Yogesh Kumar1, Bharath Loganathan2, D Vijayakumar3
1Department of Orthopaedics, SRM Global Hospitals, Chennai, Tamil Nadu, India.
Background:
Elderly osteoporotic patients with kyphosis secondary to spinal tuberculosis (TB) are at high risk for implant failure. For these patients, polymethylmethacrylate (PMMA)-augmented pedicle screw fixation provides immediate stability but increases the risk of infection. Here, we evaluated the outcome for a 78-year-old osteoporotic female with TB-related kyphosis successfully managed with PMMA-augmented pedicle screw fusion.
Case Description:
A 78-year-old female presented with mid-back pain, progressive kyphotic deformity, and increasing paraparesis. The magnetic resonance imaging revealed infectious T12-L1 spondylitis with accompanying vertebral body destruction/kyphosis. She underwent a single-stage posterior PMMA-augmented screw fixation from T9-L4 supplemented with anterior reconstruction and cage/bone grafting. The histology/cultures were consistent with spinal TB for which she received anti-tuberculosis therapy, followed by once weekly teriparatide (60 µg for 6 weeks). Neurological recovery was complete within 3 months, and by 2 years, the imaging confirmed a stable fusion.
Conclusion:
A 78-year-old osteoporotic female with T12/L1 TB-related spondylitis successfully underwent selective PMMA-augmented pedicle screw fixation from T9-L4 supplemented with anti-tubercular therapy.
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Pulmonary Tuberculosis II
Here is a detailed explanation of its pathophysiology:
Transmission: The process begins when a person inhales droplet nuclei containing M. tuberculosis. These are typically released into the air when an individual with pulmonary or...

