Related Experiment Video
Updated: Feb 4, 2026

Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Current Status of Cherenkov-Based Gamma Detectors for TOF-PET and Proton Range Verification
Gerard Ariño-Estrada1, Nicolaus Kratochwil2, Stefan Gundacker3
1Department of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA, and also with the Institut de Física d'Altes Energies, Barcelona Institute of Science and Technology, 08193 Barcelona, Spain.
Abstract:
Time-of-flight positron emission tomography (TOF-PET) and proton range verification (PRV) in proton therapy are based on the detection of gamma photons. Despite the difference in the ultimate goal and status of each of these two modalities, both heavily rely on the gamma detectors used in associated imaging systems. The emission of Cherenkov light has been studied extensively over the last decade as a gamma-detection signature in different detector configurations for TOF-PET and PRV. This review aims at: 1) capturing the breadth of works that report on using Cherenkov light for these applications from a detector instrumentation perspective and 2) summarizing barriers encountered by these approaches in their path toward commercial adoption. This review is structured in seven sections: I) brief introduction of TOF-PET and PRV needs that might be addressed with Cherenkov-based gamma detectors; II) physics of Cherenkov emission, propagation, and detection; experimental efforts in detector characterization grouped by the nature of the signals involved in the detector, i.e., III) simultaneous emission of Cherenkov and scintillation light; IV) pure Cherenkov emitters; and V) semiconductor detectors with simultaneous Cherenkov emission; Section VI consolidates the information with a special attention to challenges and potential strategies to overcome them; and Section VII concludes with a short paragraph. We hope this comprehensive review of the extensive work of researchers in this field in the last decade triggers further discussion and sparks inspiration among the community.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Strategies of Self-Presentation II: Self-Verification
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II