Interlaminar Versus Transforaminal Full-Endoscopic Lumbar Discectomy for L4-L5 Disc Herniation: Operative Time,

Tomasz Sienkiel1,2, Marcin Gaska1,2, Jakub Kalisz1,2

  • 1Department of Orthopedics, University Orthopedic and Rehabilitation Hospital, Zakopane, POL.

Cureus
|February 2, 2026
PubMed

Background L4-L5 disc herniation is a common cause of radiculopathy, yet the optimal full-endoscopic lumbar discectomy approaches: interlaminar endoscopic lumbar discectomy (IELD) or transforaminal endoscopic lumbar discectomy (TELD), remain debated due to level-specific anatomical constraints. This study compared operative efficiency, radiation exposure, complications, and clinical outcomes between IELD and TELD at the L4-L5 level. Methods A retrospective analysis of 131 consecutive L4-L5 full-endoscopic discectomies (42 IELD, 89 TELD) performed between 2021 and 2023 was conducted. Operative time, fluoroscopic dose-area product, anesthesia type, complications, and patient-reported outcomes (VAS, ODI) were recorded at baseline, 3 months, and 12 months. Temporal trends and learning-curve patterns were evaluated. Results A marked shift from IELD to TELD occurred over the study period, with TELD accounting for 90% of cases by 2023, and conscious analgesia was used in 94%. Operative time improved for both techniques, plateauing at 47 minutes for IELD and 42 minutes for TELD. Radiation exposure declined substantially for both approaches, decreasing from 160 to 120 µGym² for IELD and from 280 to 180 µGy·m² for TELD; however, TELD remained numerically higher than IELD in the late phase. All complications (five total) occurred early in the study period, with none recorded after 2022. Both approaches produced significant improvements in VAS and ODI scores, with comparable long-term clinical outcomes between groups. Conclusions Both IELD and TELD produced significant and sustained improvements in VAS and ODI, with no differences in long-term clinical outcomes. TELD showed a steeper learning-curve pattern and shorter operative times after proficiency was achieved, and it was increasingly performed under conscious analgesia. Fluoroscopy dose declined substantially over time for both approaches; however, TELD required higher radiation exposure during early adoption and remained numerically higher than IELD in late phases. Approach selection at L4-L5 should therefore prioritize anatomy, surgeon experience, and perioperative goals rather than expectations of superior long-term outcomes.

Related Concept Videos

Biological Effects of Radiation02:59

Biological Effects of Radiation

All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
17.9K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
821
Radiation: Applications01:17

Radiation: Applications

The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...
1.8K
Absorption of Radiation01:05

Absorption of Radiation

The rate of heat transfer by emitted radiation is described by the Stefan-Boltzmann law of radiation:
1.3K
Heating and Cooling Curves02:44

Heating and Cooling Curves

When a substance—isolated from its environment—is subjected to heat changes, corresponding changes in temperature and phase of the substance is observed; this is graphically represented by heating and cooling curves.
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
27.8K
Pneumonia III: Complications and Assessment01:30

Pneumonia III: Complications and Assessment

Pneumonia poses the potential for numerous complications that warrant consideration. These complications include the following:
861