A Reliable, Valid, and Efficient Goniometric Technique to Measure Scapular Protraction and Retraction
Nathan Short1, Donna Walls2, Melissa Long3
1Nathan Short, PhD, OTR, CHT, FAOTA, is Professor, Department of Occupational Therapy, Abilene Christian University, Abilene, TX; ins23a@acu.edu.
Goniometry is a reliable and valid method for measuring scapular protraction and retraction. This technique can be efficiently used by rehabilitation practitioners for assessing upper extremity function.
Area of Science:
- Biomechanics
- Rehabilitation Science
- Orthopedics
Background:
- Clinical assessment of scapular movement is complex due to intricate scapulothoracic joint biomechanics.
- Accurate measurement of scapular protraction and retraction is crucial for evaluating upper extremity function.
- Existing measurement techniques may present challenges in terms of reliability and validity.
Purpose of the Study:
- To evaluate the concurrent validity, reliability, and precision of goniometry for measuring scapular protraction and retraction.
- To establish goniometry as a dependable clinical tool for scapular assessment.
- To compare goniometric measurements with a motion analysis system.
Main Methods:
- Observational, descriptive study design involving 50 healthy adults.
- Two experienced raters performed goniometric measurements of scapular positions using specific anatomical landmarks.
- Dartfish motion analysis system was used for digital measurement, with blinded researchers analyzing data.
- Statistical analysis included interrater reliability (ICC, SEM) and concurrent validity (Pearson's r, Bland-Altman plots).
Main Results:
- Goniometric measurements demonstrated excellent interrater reliability (ICCs = .89–.99) and acceptable SEM values.
- Minimum detectable changes ranged from 1.7° to 5.3°.
- Concurrent validity was strong, with a mean variance of less than 1° compared to Dartfish analysis (r = .84–.92).
Conclusions:
- Goniometric measurement of scapular protraction and retraction is a reliable and valid technique.
- The precision and accuracy meet or exceed those of goniometric methods used for other joints.
- This method can be efficiently implemented by occupational therapists and other rehabilitation practitioners for clinical assessment.
Related Concept Videos
Reliability and Validity
Clot Retraction and Fibrinolysis
Distribution Reliability and Automation
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...