Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
A pilot study on professional cleansing protocols for PMMA resins produced by CAD/CAM and 3D printing technologies:
Martina Bonvicini1, Davide Silvestri1, Antonio Arena2
1Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy; Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance-Unit of Dentistry and Oral-Maxillo-Facial Surgery, University of Modena and Reggio Emilia, Modena, Italy.
Objectives:
This in vitro pilot study evaluated the effects of two professional cleansing protocols on surface roughness and color stability of various resins for complete dentures.
Methods:
50 resin specimens were prepared and divided into five groups (n = 10): Probase Hot (PH, Ivoclar AG), IvoBase CAD (IBC, Ivoclar AG), Ivotion Dent (ID, Ivoclar AG), Dima Print Denture Base (DPDB, Kulzer), and Dima Print Denture Teeth (DPDT, Kulzer). After a 7-day immersion in coffee solution, two cleansing protocols were applied: a chemical one using an alkaline solution, and a combined mechanical+chemical one involving an acid-based cleaning agent with a rotating needle device followed by the same chemical protocol. Surface roughness was measured before and after cleaning using a structured light profilometer (Confovis) connected to a microscope (Eclipse LV150N, Nikon). Color stability was assessed with a colorimeter (Easy_Color, SmartVision). One specimen per group underwent SEM analysis at baseline and after both protocols. The data analysis was performed by using Kruskal-Wallis test and post-hoc Dunn test for comparison.
Results:
Surface roughness was not significantly affected by either protocol (p>0.05). All ΔE values were below the perceptibility threshold (ΔE<1.2), except for ID after both the chemical (ΔE = 2.28) and the mechanical+chemical protocol (ΔE = 2.39) and DPDB after both the chemical (ΔE = 2.06) and the mechanical+chemical protocol (ΔE = 2.33).
Conclusions:
Surface roughness and color stability of PMMA resins were not affected by the tested cleansing protocols, so they could be used by clinician during the periodically control visit.
Clinical Significance:
The proposed cleansing protocols help preserve the long-term aesthetic and functional integrity of dentures, enhancing patient satisfaction and oral health.
Related Concept Videos
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
The Professional Nurse
Communication skills: These are critical characteristics, especially speaking and listening.
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Pilot and Numeric Relaying
Color Vision