Related Experiment Video
Updated: Feb 4, 2026

Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements
Published on: February 28, 2016
Ultrasensitive Gas Detection via Polarization-Mode Photothermal Interferometry in a Single-Mode Nanofiber Coupler
Pengcheng Zhao1,2, Haihong Bao1,2, Hoi Lut Ho1,2
1Photonics Research Institute, Department of Electrical and Electronic Engineering, The Hong Kong Polytechnic University, 999077 Hong Kong SAR, China.
Abstract:
Optical nanofibers (ONF) have emerged as versatile platforms for studying light-gas interactions at the micro/nanoscale, yet existing ONF gas sensors remain limited in detection sensitivity. Here, we report a polarization-mode photothermal interferometry technique that precisely measures the gas absorption-induced phase difference between two polarization states of the symmetric supermode of a single-mode ONF coupler. The high power density and large evanescent field associated with the ONF coupler enhance the efficiency of photothermal phase modulation, while the strong waveguide birefringence and noise-immune differential phase detection confer environmental immunity, jointly yielding an order-of-magnitude enhancement in the signal-to-noise ratio. With a 2 cm-long overcoupled ONF coupler, we achieved an acetylene detection limit of 6 ppb and an instability below ± 1.2% over 30 h. This compact ONF gas sensor, based on standard fused directional coupler technology, provides a promising route toward cost-effective and high-performance solutions for environmental monitoring and industrial applications.
Related Concept Videos
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Modes of Standing Waves - I
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...