Related Experiment Video
Updated: Feb 4, 2026

Assessment of Maternal Vascular Remodeling During Pregnancy in the Mouse Uterus
Published on: December 5, 2015
Reproducibility of the Amsterdam consensus criteria for maternal vascular malperfusion (MVM): a multicenter
Maria Linda Rocha1,2, Thomas Menter3, Sandra Zekic Tomas4
1Institute of Pathology, University Medicine Rostock, Rostock, Germany.
Objectives:
Maternal vascular malperfusion (MVM) refers to dysfunctional uteroplacental circulation and is associated with increased risk of adverse maternal and fetal outcomes. The diagnosis of MVM is one of the most common pathological diagnoses in term placentas. The aim of the study was to test the interrater reliability of the MVM Amsterdam criteria.
Methods:
A group of 12 international perinatal pathologists reviewed digital histological sections of placentas (n=29; 20 MVM/ 9 non-MVM controls), applying published Amsterdam workshop consensus criteria. Kappa statistics were used for interobserver agreement analysis.
Results:
Agreement levels on final MVM diagnosis according to Amsterdam consensus were calculated as slight to fair (K-values of 0.187 and 0.260, p<0.001). Substantial agreement was reached one time for infarcts (K-value of 0.707, p<0.001). Complementary tested criteria achieved none to moderate agreement.
Conclusions:
Our results highlight the need to refine current MVM criteria to support consistent international diagnosis.
Related Concept Videos
Criteria for Causality: Bradford Hill Criteria - II
Criteria for Causality: Bradford Hill Criteria - I
Seedless Vascular Plants
Criteria for Aromaticity and the Hückel 4n + 2 Rule
For the first time, Eric Hückel, a German chemical physicist, derived a set of structural features for a compound to be classified as aromatic. This is now known as Hückel’s rule or the 4n +...
Yield Criteria for Ductile Materials under Plane Stress
The Maximum Shearing Stress Criterion, also known as...
Vascular Spasm