Objective:
To examine outcomes of femoral neck fractures (FNFs) in non-geriatric adults treated with the Femoral Neck System (FNS; DePuy Synthes, Warsaw, IN) compared to three other fixation techniques.
Methods:
This was a retrospective study in two Level I Trauma Centers (2019-2024) in adults 18-50 years old with FNFs (AO/OTA 31) that underwent surgical fixation. Patients were classified by fixation method: femoral neck system (FNS), dynamic hip screw (DHS), cephalomedullary nail (CMN) device and cannulated screws (CS). Outcomes compared between groups included: rates of reoperation, union, hardware failure, avascular necrosis (AVN), conversion to total hip arthroplasty (THA), operative time, intraoperative radiation exposure, surgical site infection (SSI) and length of stay (LOS).
Results:
A total of 95 patients were included (FNS n = 27; DHS n = 15; CMN n = 15; CS n = 38). The majority of the patients were male (64.2 %), with an average age of 32.5 years and follow up time of 363 days. While being used predominantly for displaced fractures (66.7 %, p = 0.001), the FNS had significantly lower rates of hardware failure (74.1 %; p = 0.046), AVN (0 %, p = 0.034) and THA conversion (0 %, p = 0.029). CS had the highest union rates (89.5 %; p = 0.046), lowest reoperation rates (13.2 %; p = 0.030) and were used primarily for non-displaced fractures (63.2 %, p = 0.001). There were no differences among groups in surgical time (p = 0.191), or LOS (p = 0.592). A sub-analysis comparing reoperation rates after closed reduction showed that successful closed reduction was associated with not requiring reoperation (40.5 % vs 14.3 %; p = 0.026).
Conclusion:
Fixation of FNFs in young adults with the FNS has lower rates of AVN, hardware failure and THA conversion compared to other fixation methods. Fixation with screws has the highest union rate and lowest reoperation rate in this demographic. Fixation of FNFs with the FNS has similar if not better outcomes when compared to other fixation methods. However, surgical factors such as fracture displacement and closed reduction may have influenced outcomes and require further study.
Level Of Evidence:
III.
Related Concept Videos
Muscles of the Anterior Neck
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Comparative Excretory Systems
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...