Related Experiment Video
Updated: Feb 5, 2026

Isolation of Papillary and Reticular Fibroblasts from Human Skin by Fluorescence-activated Cell Sorting
Published on: May 7, 2019
Skin Uptake of 131I in a Veterinary Practice
James P Abraham1, Thomas E Johnson
1Colorado State University College of Veterinary Medicine and Biomedical Sciences, Radiation Safety Office, 141 General Services Building, 1251 South Mason Street, Fort Collins, CO 80523.
None:
Accidental trace 131I skin contamination resulted in an intake to a veterinary nuclear medicine technician at Colorado State University (CSU). The resulting dose to the technician was determined through an in-vivo measurement of radioactivity in the thyroid. Inhalation and ingestion of the isotope were ruled out due to the chemical nature of the 131I, as determined by a previous study. The CSU Radiation Control Office performed measurements of the technician's thyroid daily and then weekly to quantify the uptake [2.2 kBq (60.1 nCi)] as well as the effective half-life of 131I (7.61 days) for the technician. Establishing a technician-specific effective half-life by graphing in-vivo measurements also showed near agreement with established effective half-life determinations specified in ICRP 30 for inhalation. The university assessed the committed dose equivalent (CDE) to the thyroid using three different methods and assigned a the highest CDE calculated (4.1 mSv), and an SDE of 0.22 mSv from external contamination. The average of the CDE calculated via each method was 3.68 ± 0.38 mSv. A comparison of the 3 thyroid dose calculation methods resulted in a 10% coefficient of variation. Close agreement between the various calculations demonstrates that any of these methods would be sufficient in determining a committed effective dose to the thyroid, while providing a level of confidence to the technician that the determination is accurate and appropriate. A key aspect of this report is how even trace amounts of radioiodine on intact skin can result in measurable doses.
More Related Videos
Related Concept Videos
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Drugs Affecting Neurotransmitter Release or Uptake
Skin Cancer
Basal Cell Carcinoma (BCC): BCC is the most common type of skin cancer, accounting for about 80% of cases. It typically develops in...
Sensory Functions of the Skin
There are two main categories of receptors on the skin: capsulated and non-capsulated. The non-capsulated ones are mainly the pain receptors. The capsulated ones can be further categorized based on the...

