Related Concept Videos

Voltage Dividers01:14

Voltage Dividers

In electrical circuits, resistors can be connected in series, sequentially linked one after the other. In a series configuration, the same current flows through each resistor. Ohm's law is a fundamental principle to understand the behavior of resistors in series. It expresses the voltage across these resistors in terms of the current and resistance.
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the current...
1.3K
Current Dividers01:10

Current Dividers

In parallel electrical connections, resistors are linked between the same pair of nodes, creating an equal voltage across each resistor. Kirchhoff's current law is applied to these connections, establishing that the sum of currents through these resistors equals the source current. Utilizing Ohm's law, the source current is determined as the product of the source voltage and the sum of the reciprocals of individual resistances. This relationship simplifies the process of finding the current...
1.0K
Design Example: Resistive Touchscreen01:14

Design Example: Resistive Touchscreen

A device engineer plays a crucial role in designing user interfaces for mobile devices. One such interface is the resistive touchscreen, which fundamentally consists of two metallic layers: a flexible upper layer and a rigid lower layer, separated by a narrow gap. The high resistance between these two layers is a key characteristic of this design.
When a user touches the screen, the two layers make contact at a specific point known as the touchpoint. This contact reduces the resistance between...
739
Titrimetric Methods: Types and Commonly Used Strategies01:08

Titrimetric Methods: Types and Commonly Used Strategies

In chemistry, titrimetric methods are broadly classified into three types: volumetric, gravimetric, and coulometric. Volumetric titrations involve measuring the volume of a titrant of known concentration that is required to react completely with an analyte. In gravimetric titrations, the standard solution reacts with the analyte to form an insoluble precipitate, which is filtered, dried, and weighed. In coulometric titrations, current is applied to an electrochemical reaction until the reaction...
2.5K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
1.7K
Molecular Shape and Polarity03:37

Molecular Shape and Polarity

Dipole Moment of a Molecule
75.8K