Related Experiment Video
Updated: Feb 5, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Association of acetabular implants with sensitive radiographic surveillance on revision rates: a study based on 5 hip
Chan Hee Cho1, John M Abrahams2, Deepti K Sharma2
1Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia. chanhee.cho@adelaide.edu.au.
Background And Purpose:
National joint arthroplasty registries are the gold standard for monitoring long-term acetabular implant survivorship. Sensitive radiographic surveillance (SRS) has been recommended as a complementary surveillance approach, but no study has investigated whether implants introduced with no sensitive radiographic surveillance (NSRS) are associated with higher revision rates. Therefore, we investigated whether acetabular implants with NSRS are associated with higher revision rates than those with SRS.
Methods:
Acetabular implants with SRS were defined as those with published evidence of stability measurements assessed using either radiostereometric analysis or "Ein Bild Röntgen Analyse." Evidence of SRS of acetabular implant designs was sourced from 2 literature reviews. A mixed-effects model was used to pool and compare the revision rate of acetabular implants with SRS and NSRS at 5 and 10 years from 5 arthroplasty registries.
Results:
There were 29 unique acetabular implant designs with SRS and 86 designs with NSRS that had matching 5- and 10-year revision rates. At 5 years, there was a mean difference of 0.8% (95% confidence interval [CI] 0.5-1.1) in mean all-cause revision rates favoring implants with SRS. Mean all-cause revision rates at 10 years for acetabular implants with SRS and NSRS were 5.2% (CI 4.9-5.5) and 7.4% (CI 7.0-7.9) respectively, with a mean difference of 1.8% (CI 1.2-2.3) favoring implants with SRS.
Conclusion:
Acetabular implants with NSRS were associated with 1.8% higher pooled revision rates than those with SRS at 10 years, which represents a relative increase in acetabular revision burden of approximately 36%.
Related Concept Videos
Genome-wide Association Studies-GWAS
GWAS does not require the identification of the target gene involved in...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Principles of Disease Surveillance
Urine Studies II: Urine Culture and Sensitivity Test
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...

