Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
Published on: February 5, 2020
Evaluating and refining the wheelchair mobility activity log (WC-MAL): a comprehensive study of validity and
Tainara Rodrigues Dos Santos1, Jocemar Ilha2, Carolina Luiza Donzelini Rodrigues1
1Research group on Functionality and technological innovation in neurorehabilitation (GFIT-Neuro), Department of Physiotherapy, Universidade Federal de São Carlos, São Carlos, SP, Brazil.
Study Design:
Validity and Reliability Analysis.
Objective:
Evaluate the structural validity, reliability and criterion validity of the Wheelchair Mobility Activity Log (WC-MAL) using Rasch analysis.
Methods:
Sixty individuals with SCI and using a manual wheelchair participated in the study. The WC-MAL was employed remotely. Rasch analysis evaluated the structural validity of the instrument. The intra-rater reliability of the WC-MAL score was analysed using the random model Intraclass Correlation Coefficient (ICC) and the Standard Error of Measurement was calculated to estimate the precision of individual scores. For concurrent criterion validity, the data from the tachometer were used as the "gold standard" to assess wheelchair mobility, with the WC-MAL serving as the comparator. Pearson's correlation coefficient was used to evaluate the relationship between the tachometer data and WC-MAL Frequency Scale scores.
Results:
The Rasch analysis led to the exclusion of three items (1, 3, and 10) from the original instrument, improving model fit and refining WC-MAL 2.0. WC-MAL 2.0 demonstrated good discriminant ability with a Person Separation Reliability of 0.91-0.93 and explained variance between 59.3 and 61%. The WC-MAL 2.0 showed no local dependency, maintained unidimensionality across all scales, and exhibited no uniform Differential Item Functioning. The WC-MAL 2.0 demonstrated excellent inter-rater reliability (ICC0.84-0.91), strong internal consistency (Cronbach's alpha 0.84-0.91), and strong correlations between the Frequency Scale and tachometer data (r = 0.78, p < 0.001), supporting its criterion validity.
Conclusion:
The WC-MAL 2.0 is a suitable instrument with adequate validity and reliability for assessing wheelchair performance in individuals with SCI.
Related Concept Videos
Reliability and Validity
The Mantel-Cox Log-Rank Test
Distribution Reliability and Automation
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...