Related Experiment Video
Updated: Feb 5, 2026

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
The effect of using patient-specific guides for total knee replacement without hardware removal in complex
Chi-Pin Hsu1,2, Chun-Chieh Chen3,4,5, Yi-Sheng Chan6,7
1Department of Mechanical Engineering, Ming Chi University of Technology, New Taipei City, Taiwan.
Background:
Post-traumatic knee replacement (PTKR) is frequently complicated by the presence of retained metallic hardware around the joint, which limits the use of intramedullary alignment guides. Consequently, extramedullary jigs are often required, although they may increase radiation exposure and reduce alignment precision. Patient-specific guides (PSGs), generated from medical imaging and produced via 3D printing, offer a potential alternative for improving accuracy in complex surgical scenarios. This study aimed to assess the accuracy of PSGs in PTKR using in-vitro knee models with and without retained hardware.
Methods:
CT images of arthritic knees were used to generate 3D-printed anatomical models. Metallic plates and screws were subsequently mounted to replicate typical post-traumatic hardware configurations. These phantoms underwent CT scanning for virtual surgical planning, and patient-specific guides (PSGs) were designed based on the reconstructed preoperative models. In-vitro distal femoral and proximal tibial resections were then performed by a surgeon using the corresponding PSGs. After the simulated procedures, all phantoms were re-scanned to quantify PSG positioning accuracy and resection angles.
Results:
Knee phantoms with hardware exhibited shape deviations 17-18.5 times greater than those without hardware (p < 0.05). PSG positioning errors averaged 0.68 mm and 2.83° in hardware models, compared to 0.55 mm and 1.32° in non-hardware models. Resection angle errors in hardware phantoms ranged from 2.4° to 3.1°, significantly higher than in the non-hardware group.
Conclusions:
Based on the in-vitro experimental findings, PSGs allow PTKR to be performed without the removal of retained hardware while achieving accuracy that exceeds that of traditional extramedullary alignment techniques. Although hardware presence results in a quantifiable reduction in accuracy, PSGs continue to demonstrate improved alignment precision and contribute to enhanced workflow efficiency in the context of complex PTKR.
More Related Videos
Related Concept Videos
Post-traumatic Stress Disorder
Symptoms and Behavioral Manifestations
A spectrum of distressing symptoms characterizes PTSD. Recurrent flashbacks, where individuals involuntarily relive traumatic events,...
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Protein Complex Assembly
Many viruses self-assemble into a fully functional unit using the infected host cell to...
GIS Software, Hardware, and Sources of GIS Data
Traumatic Memory

