Related Experiment Video
Updated: Feb 5, 2026

Culturing of Human Nasal Epithelial Cells at the Air Liquid Interface
Published on: October 8, 2013
Application of a human bronchoepithelial-air-liquid interface model to assess respiratory hazard of VOCs using a
Olivia C G Lampe1,2, Eva C M Vitucci1,2, Carolyn L Cannon3
1Department of Environmental and Occupational Health, Texas A&M University, College Station, TX, USA.
Objective:
Volatile organic compounds (VOCs) are prevalent in both indoor and outdoor environments and have been linked to health effects. This study aimed to assess VOC-induced effects on the respiratory epithelium using an in vitro human bronchial epithelial air-liquid interface (ALI) model.
Methods:
A human bronchial epithelial cell line, 16HBE, was cultured at ALI and exposed to relevant concentrations of two representative VOCs, acrolein or formic acid, and matched filtered air (control) in a CelTox exposure system for two hours to replicate an acute inhalation exposure. Cells were allowed to recover for 24 h before cell lysate and culture media were collected for analysis.
Results:
Cytotoxicity, based on LDH activity, significantly increased at the highest doses tested for both VOCs. A dose-dependent increase in barrier permeability was observed for confluent cells exposed to acrolein and formic acid. Acrolein and formic acid exposure induced IL-8, TNFα, and HMOX-1 expression, genes indicative of proinflammatory signaling and oxidative stress, respectively. Formic acid, but not acrolein, exposure also increased expression of PINK1, a gene indicative of mitophagy. Benchmark concentration (BMC) modeling of in vitro acrolein data yielded a BMCL (benchmark concentration lower confidence limit) that substantiates the stringency of OSHA's 8-hour permissible exposure limit (PEL). In contrast, BMC modeling of in vitro formic acid data produced BMCLs below existing regulatory exposure thresholds.
Conclusion:
Collectively, these findings demonstrate that this model is a plausible in vitro tool to investigate VOC-induced effects on the airway and supports its utility in VOC safety evaluation.
More Related Videos
10:10Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface
Published on: February 23, 2020
09:29An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
Published on: May 13, 2020
Related Concept Videos
Model Approaches for Pharmacokinetic Data: Physiological Models
Model Approaches for Pharmacokinetic Data: Compartment Models
Two primary types of compartment models are recognized: mammillary and catenary. The more...
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...