Related Experiment Video
Updated: Feb 5, 2026

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
High-Repetition-Frequency Nanosecond Pulsed Field Ablation for Paroxysmal Atrial Fibrillation: 12-Month Outcomes From
Shuanglun Xie1, Hengli Lai2, Fengpeng Jia3
1Department of Cardiology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou & Guangdong Province Key Laboratory of Arrhythmia & Electrophysiology (S.X., J.W.).
Background:
Nanosecond pulsed field ablation, which offers potential benefits, such as reduced muscle contraction, may enable procedures to be performed under local anesthesia.To evaluate the 12-month safety and efficacy of a novel high-repetition frequency nanosecond pulsed field ablation for treating paroxysmal atrial fibrillation.
Methods:
The prospective, multicenter, single-arm trial SCENA-AF study (Safety-and-effectiveness Clinical Evaluation of Nanosecond-pulse Ablation for Atrial Fibrillation) was conducted across 11 Chinese centers. Symptomatic drug-refractory patients with paroxysmal atrial fibrillation aged 18 to 80 years underwent pulmonary vein isolation using a commercial nanosecond pulsed field ablation system. The primary efficacy end point was freedom from documented atrial fibrillation, atrial flutter, or atrial tachycardia ≥30 seconds from 91 to 365 days postablation without use of class I and III antiarrhythmic drugs. The primary safety end point was freedom from device- or procedure-related death, stroke, transient ischemic attacks, or other major complications during the procedure and 12-month follow-up.
Results:
Of the 166 enrolled patients who underwent the PFA procedures, 162 completed follow-up. Acute pulmonary vein isolation success was 100% for targeted veins. At 12 months, 88.49% (95% CI, 82.54%-92.50%) met the primary efficacy end point. No device- or procedure-related death, stroke, or transient ischemic attacks occurred. Notably, 92.77% of procedures were performed under local anesthesia and conscious sedation. Procedure-specific serious adverse events occurred in 2.41% of patients and were limited to access-site hematomas or pseudoaneurysms that resolved. No clinical hemolysis signs or symptoms were observed.
Conclusions:
The novel high-repetition-frequency nanosecond pulsed field ablation demonstrated high 12-month efficacy and a favorable safety profile for paroxysmal atrial fibrillation treatment. The ability to perform most procedures under local anesthesia with conscious sedation, with general anesthesia rarely needed, highlights a potential advantage of this technology.
Clinical Trial Registration:
www.clinicaltrials.gov; Unique identifier: NCT06039722.
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Clinical Trials: Overview