Related Experiment Video
Updated: Feb 6, 2026

A Two-interval Forced-choice Task for Multisensory Comparisons
Published on: November 9, 2018
Monocyte distribution width reference intervals in healthy Chinese adults: a study revealing the impact of
Qimei Wei1, Kun Luo1, Shanshan Dong1
1Department of Clinical Laboratory, Wuhan Asia Heart Hospital, Wuhan, People's Republic of China.
Monocyte distribution width (MDW) is a promising biomarker for early sepsis detection, but its use in Asian populations has been limited due to the lack of region-specific reference intervals (RIs). This study aimed to establish the first MDW RI for healthy Chinese adults using EDTA-K2 anticoagulant, strictly following CLSI EP28-A3C guidelines. A total of 262 samples from healthy Chinese blood donors were analyzed using a Beckman Coulter DxH 900 analyzer. Statistical methods included Shapiro-Wilk tests for normality, t-tests, ANOVA for group differences, and Spearman correlation analysis, with RIs calculated using parametric, non-parametric, and robust methods. The parametric RI limits were determined to be 14.48 (90% CI 14.16-14.80) and 21.56 (90% CI 21.24-21.88), closely aligning with results from the robust method (14.41-21.55) and non-parametric method (14.70-21.52). Our findings are consistent with Spanish data obtained using EDTA-K2 anticoagulant but differ from Italian data that used EDTA-K3, highlighting the potential impact of anticoagulant type on MDW values. This RI is unaffected by gender or age, providing a critical diagnostic tool for early sepsis detection in Chinese clinical practice and emphasizing the need for further studies to investigate anticoagulant influences for global standardization.
Monocyte distribution width (MDW) is a promising biomarker for early sepsis detection, but its use in Asian populations has been limited due to the lack of region-specific reference intervals (RIs). This study aimed to establish the first MDW RI for healthy Chinese adults using EDTA-K2 anticoagulant, strictly following CLSI EP28-A3C guidelines. A total of 262 samples from healthy Chinese blood donors were analyzed using a Beckman Coulter DxH 900 analyzer. Statistical methods included Shapiro-Wilk tests for normality, t-tests, ANOVA for group differences, and Spearman correlation analysis, with RIs calculated using parametric, non-parametric, and robust methods. The parametric RI limits were determined to be 14.48 (90% CI 14.16-14.80) and 21.56 (90% CI 21.24-21.88), closely aligning with results from the robust method (14.41-21.55) and non-parametric method (14.70-21.52). Our findings are consistent with Spanish data obtained using EDTA-K2 anticoagulant but differ from Italian data that used EDTA-K3, highlighting the potential impact of anticoagulant type on MDW values. This RI is unaffected by gender or age, providing a critical diagnostic tool for early sepsis detection in Chinese clinical practice and emphasizing the need for further studies to investigate anticoagulant influences for global standardization.
More Related Videos
05:19Choice and No-Choice Bioassays to Study the Pupation Preference and Emergence Success of Ectropis grisescens
Published on: October 30, 2018
07:08Assessment of the Anticoagulant and Anti-inflammatory Properties of Endothelial Cells Using 3D Cell Culture and Non-anticoagulated Whole Blood
Published on: September 5, 2017
Related Concept Videos
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
Bioavailability Study Design: Healthy Subjects Versus Patients
Mate Choice
Confidence Intervals
A...
Inertial Frames of Reference