Related Experiment Video
Updated: Feb 6, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Risk Factors for Nonunion Following Lateral Locked Plating of Distal Femoral Fractures: A Bayesian Analysis of 560
Robert K Wagner1,2,3,4, Stein J Janssen3,4, Mark Cote1,2
1Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts.
Background:
Lateral locked plating remains an important treatment strategy for distal femoral fractures but has been associated with nonunion rates ranging from 6% to 20%. The objective of this study was to identify factors associated with nonunion following lateral locked plating of distal femoral fractures with use of a Bayesian analysis.
Methods:
All consecutive patients ≥18 years of age who were treated with lateral locked plating for a distal femoral fracture at 2 Level-I trauma centers between 2006 and 2024 and who had ≥3 months of follow-up were included. Multivariable Bayesian logistic regression analysis was performed to identify factors associated with nonunion, which was defined as a reoperation to promote healing, and the results are reported as odds ratios (ORs) with 95% credible intervals (CrIs). Probabilities of >95% were considered very strong evidence of an association with nonunion, and probabilities of 90% to 95% were considered strong evidence.
Results:
A total of 560 patients (median age, 68 years; 29% male; 90% White; 97% non-Hispanic; 41% with distal periprosthetic fractures) were included. Fifty-four patients (9.6%) underwent reoperation to promote healing. There was very strong evidence that multifragmentary comminution of the metaphysis (versus simple fracture: OR, 2.60; 95% CrI, 0.91 to 8.06), medial cortical comminution of >0 to 25 mm (versus 0 mm: OR, 3.11; 95% CrI, 1.35 to 7.48), and varus (lateral distal femoral angle [LDFA] of ≥84°: OR, 3.04; 95% CrI, 1.46 to 6.51) or valgus (LDFA of ≤78°: OR, 2.42; 95% CrI, 0.96 to 5.99) malalignment increased the odds of nonunion. A screw density of ≤0.60 proximal to the working length reduced the odds of nonunion (versus ≥0.81: OR, 0.40; 95% CrI, 0.16 to 0.95), although the size and certainty of this effect varied in the sensitivity analysis that utilized alternative thresholds. There was strong evidence that obesity increased the odds of nonunion (OR, 1.64; 95% CrI, 0.86 to 3.13) and that intact wedge fractures reduced the odds of nonunion (versus simple fracture: OR, 0.35; 95% CrI, 0.05 to 1.74).
Conclusions:
One in 10 patients developed nonunion and underwent reoperation to promote healing. Surgeons should restore coronal plane alignment and may consider augmenting fixation in the presence of multifragmentary comminution. Constructs in which all screw holes proximal to the working length are filled should be avoided, although the optimal configuration remains unclear and depends on other construct characteristics influencing biomechanics. Overall, the small to moderate effect sizes highlight the multifactorial etiology of nonunion following lateral locked plating of distal femoral fractures.
Level Of Evidence:
Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
More Related Videos
05:42Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
Published on: March 3, 2023
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Factors Affecting Protein-Drug Binding: Patient-Related Factors
Age stands as a key determinant in protein-drug binding. Neonates, characterized by low albumin content, experience heightened concentrations of unbound drugs such as phenytoin and...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Transcription Factors
Relative Risk
Lateralization