Related Experiment Video
Updated: Feb 6, 2026

Author Spotlight: Exploring Dynamic Neural Changes Associated with Religious Chanting
Published on: May 31, 2024
3DFE-Net: Three-dimensional fusion enhancement network based on multi-attention mechanism for multi-modal magnetic
Mengjiao Jin1,2, Yuanjun Wang3
1Institute of Medical Imaging & Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Abstract:
Nowadays, the research of image fusion methods focuses on two-dimensional medical images, and almost no three-dimensional medical image fusion methods based on deep learning have been proposed. However, 3D image fusion is significant in clinical diagnosis. Therefore, this paper proposed a 3D medical image fusion enhancement network (3DFE-Net) for the gap in deep learning. 3DFE-Net included a feature extraction module, a multi-attention fusion module, and a feature reconstruction module. Firstly, multi-receptive field convolution blocks (MRFC) and multi-receptive field bottleneck blocks (MRFB) were devised instead of the traditional convolutional blocks to extract features of multiple receptive fields. Then, the multi-attention fusion module was designed using channel attention, self-attention, and spatial attention to make the network focus on the critical information in source images. Finally, the 3D fused image was obtained by the feature reconstruction module. In addition, a multivariate loss function was proposed for network training so that the fused image retains more edge structural information and texture details. MR-T1ce/MR-T2 fusion experiments show that, compared with the traditional method, 3DFE-Net improved the evaluation metrics EN (Information Entropy), MI (Mutual Information), SD (Standard Deviation), Qabf (Quality assessment of binary), and VIF (Visual Information Fidelity) by 0.0501, 0.1003, 5.2682, 0.1874, and 0.2129, respectively. 3DFE-Net can focus on the glioma lesion region in glioma slice fusion to achieve outstanding results and keep the structural information in MR-T1ce and the brightness information in MR-T2 well in normal slices. In qualitative and quantitative evaluations, 3DFE-Net performs better than conventional methods.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
08:42Using Multi-fluorinated Bile Acids and In Vivo Magnetic Resonance Imaging to Measure Bile Acid Transport
Published on: November 27, 2016
Related Concept Videos
Magnetic Resonance Imaging
Multi-input and Multi-variable systems
In the absence of...
Imaging Studies IV: Magnetic Resonance Imaging
Multi-Step Reactions
Multi-species Conserved Sequences
Although the genome of each species varies greatly from each other, a few sequences are highly conserved. Such conserved...
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...