Related Experiment Video
Updated: Feb 6, 2026

Author Spotlight: A Pharmacodissection Approach to Uncover Mechanisms in Cardiovascular Disease Risk Populations
Published on: July 21, 2023
Ophthalmic insights into systemic microvascular dysfunction for early detection of HFpEF: a narrative review
Sukruth Pradeep Kundur1, Yathavi Charavanamuttu1, Krishan Manivannan1
1Faculty of Life Sciences and Medicine, King's College London, London, UK.
Abstract:
Heart failure with preserved ejection fraction (HFpEF) is a complex clinical syndrome characterized by diastolic dysfunction in the context of elevated left ventricular filling pressures leading to clinical symptoms such as dyspnea, fluid retention and lethargy. Systemic microvascular dysfunction plays a key role in the pathophysiology of HFpEF, contributing to impaired tissue perfusion, endothelial dysfunction, and increased cardiovascular morbidity. Due to significant morbidity and mortality associated with the condition, there is a clear need for early detection and risk stratification. This narrative review aims to explore the use of retinal imaging as a non-invasive tool for detecting systemic microvascular dysfunction and its implications as a biomarker for HFpEF. A comprehensive search of the literature was performed, and relevant studies were identified for inclusion based on their relevance to microvascular dysfunction and retinal changes in HFpEF. While N-terminal pro-B-type natriuretic peptide (NT-proBNP) and transthoracic echocardiography remain the diagnostic gold standard, retinal vascular changes have shown potential for both diagnostic and prognostic applications in HFpEF. Retinal biomarkers provide unique insights into microvascular dysfunction. Early studies support integrating these biomarkers for detection and risk stratification in future clinical guidelines. However, further research is needed to validate their predictive value and feasibility as standardized biomarkers for HFpEF assessment.
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Second Order systems II
First Order Systems
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
Second Order systems I
By reinterpreting the system, one can derive the closed-loop transfer function, which...
Thermodynamic Systems
Consider an example of tea boiling in a kettle. The...

