Related Experiment Video
Updated: Feb 6, 2026

Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis
Published on: May 8, 2014
3D-printed shoe soles with structural properties towards reducing knee adduction moments during walking
Ziang Jiang1, Paciane Bo Studer2, Matthias Zäh2
1Institute for Biomechanics, ETH Zürich, Zürich, Switzerland.
Purpose:
Lateral wedged insole (LWI) is a representative foot orthosis for the conservative management of knee osteoarthritis. However, recent research indicates the heterogeneity of LWIs' biomechanical effectiveness, indicating limitations in conventional LWI design and the need to develop new orthoses with improved effects. This study evaluated the efficacy of custom-designed 3D-printed shoe soles in reducing knee adduction moment (KAM), compared with conventional 5° LWIs.
Methods:
Shoe soles were 3D-printed with a gyroid infill structure to allow adjustable stiffness, generating a variable stiffness (VS) sole with lateral-medial stiffness differentiation, and a soft heel (SH) sole incorporating the same differentiation plus a soft heel. Twenty-one healthy adults performed gait assessments wearing control shoes with neutral insoles, control shoes with 5° LWIs, VS, or SH shoes. Kinematic data and ground reaction forces (GRFs) were captured. Gait parameters, joint kinematics and kinetics were analysed. Repeated measures ANOVA assessed footwear effects, and multiple linear regression identified key contributors to KAM variation. Statistical significance was set at P < 0.05.
Results:
KAM varied significantly across footwear. SH shoes reduced 1st and 2nd peak KAMs by 10.5% (P = 0.001) and 8.6% (P = 0.032); VS shoes reduced the 2nd peak by 9.1% (P = 0.014). Both VS and SH reduced knee adduction angular impulse (KAAI) by 9.7% and 11.8% (P < 0.001). 5° LWIs only reduced 1st peak KAM by 7.9% (P = 0.009). GRF-knee lever arm was the main contributor to 1st peak KAM changes in VS shoes, while SH shoes' effects involved both GRF and lever arm. For 2nd peak KAM, the lever arm was dominant contributor; for KAAI, lever arm and stance time were main contributors.
Conclusion:
3D-printed soles reduced KAM variables more effectively than 5° LWIs, supporting their potential for biomechanically optimised footwear upon further assessments on individuals with knee osteoarthritis.
Related Concept Videos
Structural Properties and Dimensions of Lumber
The strength characteristics of...
Structure and Physical Properties of Alkynes
In nature, compounds containing both carbon and hydrogen are known as "hydrocarbons". Aliphatic hydrocarbons are compounds whose molecules contain saturated single bonds (i.e., alkanes) or unsaturated double or triple bonds. Alkenes contain carbon–carbon double bonds and have a structural formula CnH2n. Unsaturated hydrocarbons containing carbon–carbon triple bonds are called "alkynes" and are structurally represented by the formula CnH2n-2.
The...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Moment of Inertia
If a rigid body is rotating about an axis but is not in translational motion, its translational kinetic energy is zero. However, since each particle undergoes rotational motion, it possesses non-zero velocity and kinetic energy. Thus, the kinetic energy of the rigid body, which is the sum of the...
Principal Moments of Area
The principal moment of inertia axes are the...
Moment-Area Theorems
The theorem is divided into two parts. The first part connects the angle between tangents at any two points on the beam's elastic curve to the area under a curve derived by...

