Implementation and Performance of First-Trimester Referral Ultrasound Scan Following the Introduction of National
Grazia Volpe1, Laura Sarno2, Elena Mantovani3
1Prenatal Diagnosis and Fetal Surgery Unit, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Milan, Italy.
National guidelines for first-trimester ultrasound (US) successfully implemented in Italy for fetal anomaly detection. Expert-led early anatomy scans show high accuracy, enabling timely diagnosis of structural fetal anomalies.
Area of Science:
- Prenatal diagnostics
- Fetal medicine
- Medical imaging
Background:
- National guidelines for first-trimester ultrasound (US) referral scans were published in Italy.
- Fetal Medicine units implemented these guidelines to assess fetal anatomy in early pregnancy.
- Cases were referred for expert assessment due to increased risk for structural anomalies.
Purpose of the Study:
- To evaluate the implementation of national first-trimester referral US guidelines in Italy.
- To assess the diagnostic performance of first-trimester US in identifying fetal anomalies.
- To determine the agreement between first and second-trimester referral scans.
Main Methods:
- A multicenter, retrospective study included singleton pregnancies referred for specialized US between 11 and 14 weeks' gestation.
- Referral criteria included nuchal translucency (NT) ≥ 3.5 mm or suspected anomaly.
- Diagnostic accuracy was compared between first-trimester US and follow-up scans at 14-16 or 19-21 weeks.
Main Results:
- 322 out of 344 (93.6%) cases underwent timely first-trimester referral US.
- Agreement between 11-14 week and 19-21 week scans was 85.3% (Sensitivity 82.0%, Specificity 88.0%).
- Agreement between early scans and 14-16 week scans was 91.3% (Sensitivity 90.7%, Specificity 92.1%).
Conclusions:
- The study confirms successful implementation of national first-trimester referral US guidelines in Italy.
- First-trimester fetal anatomy assessment by experienced operators is feasible.
- High diagnostic accuracy in the first trimester enables early detection of structural fetal anomalies.
More Related Videos
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
03:47Author Spotlight: Workflow for Integrating POCUS Data into EHR for Managing Heart Failure Patients
Published on: July 12, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
National Nursing Organizations I
National Nursing Organizations II
The AACN emphasizes a healthy work environment through six standards to achieve an optimal patient outcome. The standards are appropriate staffing, meaningful recognition, collaboration, authentic leadership, effective communication, and decision-making. In addition, AACN provides certification programs, webinars, journals, and...
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.
Leaky Scanning
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...