A biomechanical evaluation of wired sternal fixation augmented with a bio-active adhesive using full coverage and
Amatulraheem Al-Abassi1, Emily Deignan2, Scott Brandon2
1Department of Biomedical Engineering, Toronto Metropolitan University, Toronto M5B 2K3, Ontario, Canada.
Abstract:
The use of bio-adhesives in sternal fixation aims to mitigate complications commonly associated with median sternotomy, which can lead to significant morbidity and mortality rates. Bio-adhesives are recognized for enhancing sternal fixation and limiting hemisterna displacement. This study evaluates the effectiveness of glass polyalkenoate cements (GPCs) derived from a novel BT101 glass in conjunction with a new spot weld application technique. Finite element analysis (FEA) was used to predict the minimum GPC adhesive coverage necessary to prevent pathological displacement of the hemisterna. Three sternal fixation models with varying GPC adhesive coverage 50%, 62.5%, and 75% were developed in SolidWorks and analyzed in Ansys software. The simulations applied a breathing load of 500 N and a wiring clamping force of 1000 N to replicate experimental conditions. The FEA results demonstrated a 21.4% reduction in directional displacement of the sternum with full adhesive coverage compared to traditional wire-only fixation. The maximum directional deformation for 50%, 62.5%, 75%, and 100% of adhesive coverage are 1.576 ± 0.232 mm, 1.281 ± 0.182, 0.999 ± 0.0262, and 0.29 ± 0.28, respectively, all of which are below the pathological displacement threshold of 2.0 mm. The findings indicate that increased adhesive coverage correlates with reduced sternal displacement. Consequently, the study recommends using wired sternal fixation enhanced with 75% GPC spot welds to minimize hemisterna displacement, potentially enhancing ossification and bone healing, and improve vascularization between the sternal halves at the spaces between adhesive spots. Thus, the development of the sternal fixation finite element model could be useful in parallel with the experimental analysis.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
05:48Lung Fixation under Constant Pressure for Evaluation of Emphysema in Mice
Published on: September 26, 2019
Related Concept Videos
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Magnetic Field Due to Two Straight Wires
Household Wiring And Electrical Safety
Magnetic Field Due To A Thin Straight Wire
Magnetic Force On Current-Carrying Wires: Example