Determining the influence of variable additive, filler, and dye concentrations in plastics on their fluorescence
Maximilian Wohlschläger1, Markus Bonauer2, Manuela List2
1Faculty of Engineering Sciences, Rosenheim Technical University of Applied Sciences, Hochschulstraße 1, 83024, Rosenheim, Germany. maximilian.wohlschlaeger@th-rosenheim.de.
Abstract:
Microplastic (MP) pollutes our terrestrial and aquatic ecosystems due to their uncontrolled discharge into our environment. The analysis of MP contamination is still a challenge, although significant improvements are made for different environmental matrices. Using mass-based particle analysis methods such as thermal extraction and desorption-gas chromatography/mass spectroscopy (GC/MS) or pyrolysis GC/MS, essential parameters such as the MP's morphology, size, and shape cannot be obtained, which are indispensable to assess the hazard of the respective particles. Raman, micro-Fourier transform infrared, and attenuated total reflectance spectroscopy are particle-based analysis methods, which are time-consuming due to the high purification effort. Thus, novel, reliable, and time-efficient methods for MP analysis are required. Previously, studies showed the potential of frequency domain fluorescence lifetime imaging microscopy (FD-FLIM) to identify plastics' type, shape, size, and morphology, and distinguishing these from natural materials. However, only pure plastic granules were investigated, omitting that commodity plastics accumulating in our environment contain various additive, filler, or dye concentrations. To circumvent the dependency of additive, filler, and dye concentrations, we investigated the fluorescence spectra and lifetimes of three plastic types, individually composed with two fillers, three additives, and two dyes in six different concentrations. We heuristically modeled the dependency of the concentration on plastics' fluorescence lifetime using a logarithmic model with a high correlation and showed that identifying the plastic types is hardly possible when fillers, additives, or dyes are added in various concentrations because of their superimposing fluorescence lifetimes. However, further research has to be conducted to investigate different emission states of fluorescence to optimize the FD-FLIM method, as only one excitation wavelength and emission band was used for the investigations.
More Related Videos
10:04Collecting Variable-concentration Isothermal Titration Calorimetry Datasets in Order to Determine Binding Mechanisms
Published on: April 7, 2011
14:34Determination of Tripartite Interaction between Two Monomers of a MADS-box Transcription Factor and a Calcium Sensor Protein by BiFC-FRET-FLIM Assay
Published on: December 25, 2021
Related Concept Videos
Additives and Fillers in Concrete
The...
Plastic Behavior
Variables Affecting Phosphorescence and Fluorescence
Concentration Cells
Consider the following voltaic cell:
Causes of Social Behavior III: Biological and Environmental Influences
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...