Related Experiment Video
Updated: Feb 7, 2026

Optic Nerve Sheath Point of Care Ultrasound: Image Acquisition
Published on: August 18, 2023
Optic nerve sheath diameter as a real-time biomarker for epidural blood patch efficacy after post-dural puncture
Kaissar Sassi1, Rachel Fresquet2, Marie-Lucie Dubois2
1Department of Anesthesiology, CHU de Toulouse, Toulouse, France. kaissar_sassi@yahoo.fr.
Abstract:
Post-dural puncture headache (PDPH) following epidural anesthesia remains a frequent obstetric complication. While epidural blood patch (EBP) is the reference treatment, its efficacy assessment still relies on subjective pain reporting. This study explored whether changes in optic nerve sheath diameter (ONSD) measured by ultrasound could serve as an objective, real-time indicator of early EBP response. In this prospective, single-center observational study, 30 postpartum patients with PDPH undergoing EBP had ONSD measured before (H0) and 2 h after (H2) the procedure. Correlation between ΔONSD and ΔVAS pain scores was analyzed with bootstrap validation, and receiver operating characteristic (ROC) analysis identified thresholds associated with early response. Mean ΔONSD was 0.97 ± 0.55 mm, significantly correlated with pain reduction (r = - 0.64, p < 0.001; bootstrap 95% CI: -0.81 to - 0.36). ROC analysis showed good diagnostic performance (AUC = 0.96, 95% CI: 0.87-1.00), with a ΔONSD ≥ 0.40 mm threshold providing 100% sensitivity and 83% specificity for early improvement. These preliminary findings suggest that ONSD ultrasound may offer a feasible, noninvasive adjunct for assessing early EBP response in PDPH. The identified 0.40 mm change threshold appears promising but requires confirmation in larger, multicenter studies with extended follow-up to determine its reproducibility and clinical utility.
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Blood and Nerve Supply to the Bones
Nutrient Artery
The nutrient artery is the main blood vessel that enters the diaphysis via the nutrient foramen. While most long bones have only one nutrient foramen, large bones, such as the femur, may have two. This...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Blood and Nerve Supply to the Kidney
Bloody Supply to the Kidneys:
The kidneys receive their blood supply from the renal arteries, which branch off from the abdominal aorta—the main artery supplying the abdomen and lower body. The renal arteries enter the kidneys at the hilum, a notch on the medial side of...
Long-patch Base Excision Repair
Self-Efficacy

