Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
Long-Lived Phosphorescent CDs@SiO2 Coupled with Magnetic Quencher Fe3O4@PDA: A Dual-Mode Lateral Flow
Qianqian Jiang1, Renlong Chen1, Tong Zhang1
1School of Chemistry and Chemical Engineering, Anhui University of Technology, Maanshan, Anhui 243032, China.
Abstract:
Lateral flow immunochromatographic assay (LFIA) features advantages such as a rapid analysis process, interpretable detection results, and low cost, making it an effective method for on-site detection of pesticides. However, the existing LFIA technologies still face bottleneck issues, including strong background fluorescence interference from the substrate and insufficient detection sensitivity for low pesticide residue levels. Here, long-lived room-temperature phosphorescent carbon dots embedded in silica (CDs@SiO2) were developed to overcome background fluorescence interference. Fe3O4 coated with dopamine (Fe3O4@PDA) was utilized for the enrichment of target pesticide molecules. Meanwhile, by virtue of the quenching effect of Fe3O4@PDA on CDs@SiO2, colorimetric and phosphorescent dual-mode LFIA technology was designed for the detection of the pesticide acetamiprid. Through the integration of the advantages of CDs@SiO2 and Fe3O4@PDA, the limit of detection (LOD) for acetamiprid was as low as 0.271 ng/mL, and satisfactory recoveries were achieved in real samples. This research breaks through the millisecond-level lifetime limitation in traditional time-resolved fluorescence immunoassays, providing novel insight for the development of labeling materials for LFIA.
More Related Videos
08:46A "Dual-Addition" Calcium Fluorescence Assay for the High-Throughput Screening of Recombinant G Protein-Coupled Receptors
Published on: December 2, 2022
07:40Field Postmortem Rabies Rapid Immunochromatographic Diagnostic Test for Resource-Limited Settings with Further Molecular Applications
Published on: June 29, 2020
Related Concept Videos
Photoluminescence: Fluorescence and Phosphorescence
A pair of electrons in a...
Variables Affecting Phosphorescence and Fluorescence
Fluorescence and Phosphorescence: Instrumentation
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Lateralization