Related Experiment Video
Updated: Feb 7, 2026

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
Active detection of melanoma via a dual-extraction-driven flexible microneedles sensor
Min Wu1, Songlong Jiao2, Lei Liu1
1School of Mechanical Engineering, Southeast University, Nanjing, 211189, People's Republic of China.
Abstract:
Wearable microneedles (MNs) biosensors offer significant potential for minimally invasive biomarker detection in interstitial fluid (ISF). However, suboptimal fluid collection efficiency, dermal irritation due to rigid structural components, and inadequate long-term operational stability collectively represent critical barriers to their clinical translation for early disease diagnosis. Here, we propose a fully integrated dual-extraction-driven flexible microneedles (DFMN) sensor for active detection of melanoma-associated miRNA. The DFMN sensor comprises hydrogel MNs, hollow Au-Ag NPs functionalized flexible electrodes, and a miniaturized wireless module. The synergistic combination of passive diffusion driven by hydrogel MN swelling and active transport via reverse iontophoresis enhanced ISF extraction volume by 1.6-fold within 5 min. This dual-extraction mechanism enabled real-time wireless detection of miRNA-221 with an ultra-low limit of detection (LOD) of 43 aM. Furthermore, to enhance reliability in complex biological environments, an artificial neural network algorithm was implemented, achieving a correlation coefficient (R2) of 0.985. The DFMN sensor holds broad application prospects in interdisciplinary fields such as human-machine interaction, smart healthcare, and artificial intelligence, providing an innovative solution for real-time sensitive detection of wearable flexible sensors.
Related Concept Videos
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
Xylem and Transpiration-driven Transport of Resources
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
Extraction: Effects of pH

