Background:
Auditory hallucinations are among the most disabling symptoms in individuals with schizophrenia (SZ) and are linked to aberrant signaling within deep-striatal circuits, such as the nucleus accumbens (NAc) and caudate head (CH). However, causal tests of striatal involvement have been limited by the inaccessibility of these structures using noninvasive neuromodulatory techniques. Low-intensity focused ultrasound (LIFU) provides millimeter-scale precision capable of modulating deep-brain circuits, but its feasibility and impact on hallucinations in SZ remain unknown.
Methods:
SZ participated in a within-subject cross-over feasibility trial including two active LIFU sessions (NAc, CH) and one sham control (unfocused sonication), spaced one-week apart. Resting-state fMRI and hallucination symptoms were acquired at baseline and immediately post-sonication.
Results:
LIFU was delivered safely and well-tolerated in all patients. Acoustic simulations show consistent engagement of both striatal targets across subjects. Clinically, SZ demonstrated significant reductions in hallucination severity following active LIFU to NAc and CH, relative to baseline. Mechanistically, SZ exhibited abnormally high striatal-superior temporal cortex (STC) connectivity at baseline. Immediately after sonication, active LIFU to NAc and CH produced robust reductions in striatal-STC coupling in SZ.
Conclusions:
This first-in-human study demonstrates that deep striatal LIFU is safe, feasible, and produces functional-connectivity changes accompanied by hallucination severity reductions in SZ. The convergence of symptom improvement with reduced striatal-STC coupling provides mechanistic proof-of-concept evidence that this circuit provides a promising biomarker and therapeutic LIFU target in psychosis and motivates larger sham-controlled trials to test the causal role of striatal circuitry in hallucination generation in SZ.
More Related Videos
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
13:41Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia: A Feasible Treatment Method in a Murine Rhabdomyosarcoma Model
Published on: January 13, 2023
Related Concept Videos
Positive Symptoms Schizophrenia: Hallucinations and Delusions
Hallucinations
Hallucinations in...
Positive Symptoms of Schizophrenia: Hallucinations and Delusions
Thought Disorders
Disorganized and unusual thought processes mark thought disorders in schizophrenia. One key feature is disorganized speech, where an individual's conversation includes...
Functions of Connective Tissues
Hard connective tissues, such as bones and cartilage, provide structure and support to the body.
Network Function of a Circuit
Schizophrenia
Biological Causes of Schizophrenia
Genetic Factors in Schizophrenia
The genetic basis of schizophrenia is strongly supported by family and twin...